42
Floor Standing, Concealed Floor Standing Type (P1, R1):
1.  Remove the screw at the bottom left of the front panel 
using a Phillips head screwdriver. (Be sure to replace the 
screw when cleaning is finished.)
2.  Remove the filter by pulling it toward you.
CAUTION
1.  Certain metal edges and the condenser fins are sharp 
and may cause injury if handled improperly; special 
care should be taken when you clean these parts.
2.  Periodically check the outdoor unit to see if the air 
outlet or air intake is clogged with dirt or soot.
3.  The internal coil and other components of the outdoor 
unit must also be cleaned periodically. Consult your 
dealer or service center.
Care: After a prolonged idle period
Check the indoor and outdoor unit air intakes and outlets for 
blockage; if there is a blockage, remove it.
Care: Before a prolonged idle period
●  Operate the fan for half a day to dry out the inside.
●  Disconnect the power supply and also turn off the circuit 
breaker.
●  Clean the air filter and replace it in its original position.
● 
Outdoor unit internal components must be checked and 
cleaned periodically. Contact your local dealer for this service.
Screw
Screw
Air filter
Air filter
Anti-Mold Filter
The anti-mold filter behind the front panel should be checked 
and cleaned at least once every two weeks.
How to remove the anti-mold fi lter
1.  Grasp both ends of the front panel and pull forward and up 
to open the front panel.
2.  Lift the anti-mold filter up slightly to disengage it from the 
protrusions on the unit.
3.  Pull downward to remove the filter from the unit.
Cleaning
Use a vacuum cleaner to remove light dust. If there is sticky 
dust on the filter, wash the filter in lukewarm, soapy water, rinse 
it in clean water, and dry it.
How to replace the anti-mold fi lter
1.  Insert the top of the anti-mold filter, and then secure the 
bottom of the filter with the protrusions on the unit.
2.  Close the front panel by pushing the center of the front 
panel and then pressing both edges until the panel clicks 
into place.
1
2
2
Cleaning the main unit and remote control unit
●  Wipe clean using a soft, dry cloth.
●  To remove stubborn dirt, moisten a cloth in warm water no 
hotter than 104°F, wring thoroughly, and then wipe.
●  The front panel can be removed in order to wash it with 
water.
Removing and remounting the front panel
Removing
Open the front panel until it is nearly horizontal, grasp the 
sections near the front panel arms on both sides, and then 
remove the panel by pushing the arms towards the outside 
while pulling the panel towards you. If the front panel is difficult 
to remove, grasp both ends of it and lift it up slightly. Move it to 
the left and disengage the left arm, then move it to the right and 
disengage the right arm.
Front panel
Protrusions
Anti-mold filter
Front panel
Arm