41
Care and Cleaning
WARNING
1. For safety, be sure to turn the air conditioner off and
also to disconnect the power before cleaning.
2. Do not pour water on the indoor unit to clean it. This
will damage the internal components and cause an
electric shock hazard.
Air intake and outlet side (Indoor unit)
Clean the air intake and outlet side of the indoor unit with a
vacuum cleaner brush, or wipe them with a clean, soft cloth.
If these parts are stained, use a clean cloth moistened with
water. When cleaning the air outlet side, be careful not to force
the vanes out of place.
CAUTION
1. Never use solvents or harsh chemicals when cleaning
the indoor unit. Do not wipe plastic parts using very
hot water.
2. Some metal edges and the fins are sharp and may
cause injury if handled improperly; be especially
careful when you clean these parts.
3. The internal coil and other components of the outdoor
unit must be cleaned regularly. Consult your dealer or
service center.
Air fi lter
The air filter collects dust and other particles from the air and
should be cleaned at regular intervals as indicated in the table
below or when the filter indication (
) on the display of the
remote control unit (wired type) shows that the filter needs
cleaning. If the filter gets blocked, the efficiency of the air
conditioner drops greatly.
Type Period
L1 6 months
D1 2 weeks
K1 2 weeks
P1, R1 2 weeks
NOTE
The frequency with which the filter should be cleaned depends
on the environment in which the unit is used.
<How to clean the fi lter>
1. Remove the air filter from the air intake grille.
2. Use a vacuum cleaner to remove light dust. If there is
sticky dust on the filter, wash the filter in lukewarm, soapy
water, rinse it in clean water, and dry it.
<How to remove the fi lter>
1-Way Cassette Type (D1):
1. Remove the 2 screws which fasten each of the 2 grilles in
place. (Reattach the two screws after cleaning.)
2. Slide the intake grille hooks (2 locations) in the direction of
the arrow to open the intake grille.
3. When the intake grille is open, use a flathead (minus)
screwdriver to press on the rear hinge tabs (2 locations),
then remove the intake grille.
2-Way Cassette Type (L1):
Grasp the intake grille, then pull it forward and allow it to drop
open. Release the latch of the filter, grasp the handles and
remove the air filter.
Wall Mounted Type (K1): 22, 28, 36 types
1. Move the flap on the air outlet grille to its lowest position
with the remote control unit.
2. The filter is disengaged by pushing the tab up gently. Hold
the air filter by the tab at the bottom, and pull downward.
When replacing the filter, make sure that the FRONT mark is
facing you. Push it up until you hear it click back into position.
Wall Mounted (K1): 45, 56, 73, 106 types
Casing and Grille (Indoor Unit)
Clean the casing and grille of the indoor unit with a vacuum
cleaner brush, or wipe them with a clean, soft cloth.
If these parts are stained, use a clean cloth moistened with a
mild liquid detergent. When cleaning the grille, be careful not to
force the vanes out of place.
CAUTION
1. Never use solvents, or harsh chemicals when cleaning
the indoor unit. Do not wipe the plastic casing using
very hot water.
2. Some metal edges and the fins are sharp and may
cause injury if handled improperly; be especially
careful when you clean these parts.
3. The internal coil and other components of the outdoor
unit must be cleaned every year. Consult your dealer
or service center.
Press on the tabs
with a flathead
(minus) screwdriver
while pulling out the
intake grille.
Slide
Hinge
Hook
Intake grille
Air intake grille
Air filter
Air filter
Air filter handle
Intake grille
Latch
PanaIndoor-337012Eng.indb41PanaIndoor-337012Eng.indb41 2012/03/2116:20:562012/03/2116:20:56