still pressing the STOP button, press the Forward Skip/Search
button for at least 2 seconds. The unit enters Self-Diagnostic
Mode and display “TEST”. Then an error code (e.g. H01) is
displayed, if any. In the case of no error, “TEST” is displayed on
FL.
4. If more than 1 error exists, the display will sequentially show the
respective error codes each time the STOP button is pressed.
8.2. Cassette Mechanism Test (For error code H01, H02, H03, H06,
F01, F02)
1. Load a cassette tape with the erasure prevention tab, remove
from left side only and close the cassette holder.
2. Press "Forward Skip/Search" (Tape will be stop after 2 seconds).
3. Load a cassette tape with the erasure prevention tab, remove
from right side only and close the cassette holder.
4. Press "Reverse Skip/Search" (Tape will be stop after 2 seconds).
5. Load a pre-recorded tape with both side record tabs intact and
close the cassette holder.
6. Press "Tape Play" (After TPS function, tape will stop
automatically).
7. Press "Tape Record" (Tape will not move).
8. Press "Stop" to indicate Error code.ve).
~ If several problem exist, error code will change each time when
"Stop" is pressed.
(e.g. H01 H03 F01 ..... etc.)
8.3. Clearing all error code
1. Press and hold STOP button for 5 seconds.
2. FL indicator shows “CLEAR” for 1 second and change to “TEST”.
8.4. Cancelling the Self-Diagnostic mode
1. Press the “Power” button to turn off the system. Press the
“Power” button again to turn on the system.
8.5. Description of error code