8.6.3. Power Supply & Digital Amplifier Error Code Table
Error
Code
F61 The abnormalities In normal operation, when DCDET2 goes Press [ STOP] on main
in an output or power to "L" (Low) (Not during POWER OFF unit for next error.
supply circuit of condition), F61 appears on FLDisplay
POWER AMP for 1 second and PCONT goes to
"L" (Low).This is due to speaker output
has DC voltage or fan is not working.
F76 Abnormality in the In normal operation when DCDET1 is Press [ STOP] on main
output voltage of detected "L" (Low) for two consecutive unit for next error.
stabilized power times, F76 is displayed on FL for
supply 1 second and after that PCONT will be
turned to "L" (Low). This is due to any of
the DC voltages (+9V, +7V, -7V, +5V,
+5.3V etc.) C22 not available.