1. Purpose
Restrict a function for hotels.
2. Access command
·
Enter to the Service 2 Mode.
·
Press Status button on remote control and entry to the
EAROM EDITOR Mode.
·
Set the data of EEPROM(ADDRESS 140) to 80.
·
Press the OK button to memorize the data.
Push the Power switch(button) off/on the set(the remote
control) to turn the set off/on.
It can be made Hotel mode.
3. Exit command
·
First, set the data of EEPROM(ADDRESS 140) to 00.
Next, Push the Power switch(button) off/on the set(the
remote control) to turn the set off/on.
Then, it is no longer hotel mode.
4. Access command to the Hotel mode setup menu
·
<Prerequisite> : It is conditions that the data of
EEPROM(ADDRESS 140) is 80.
In order to display the Hotel mode setup menu, please
enter the following command (within 2 second).
[TV]:down + [REMOTE]:TV/AV(3 times)
Then, the Hotel mode setup menu is displayed.
5. Explain the Hotel mode setup menu
CAUTION
This setup is not valid, unless data of
EEPROM(ADDRESS 160) will be C0, even if each
settings were done.
item Function
Initial INPUT Select input signal modes.
Set this signal, each time power is switched on.
<Selection> :
Off/TV/AV1/AV2/AV2S/AV3/Av3S/AV4/Av4S/AV4
C/PC
·
Off: give priority to a last memory. However,
Euro model is compulsorily set to TV.
·
AVnS/AVnC: only Euro model selectable
·
PC: selectable with VGA option
Initial VOL level Adjust output Volume.
Set this volume, each time power is switched on.
If the value of InitVol is changed, volume will
change. However, priority is given to a last
memory when InitVol is Off. When "InitVol" is
larger than "MaxVol", make "InitVol" and "MaxVol"
the same.
<Selection/Range> :
Off/0 to 100
·
Off: give priority to a last memory
Maximum VOL
level
Adjust maximum volume.
Set this max. volume, each time power is
switched on.
When "MaxVol" is smaller than "InitVol", make
"MaxVol" and "InitVol" the same, if "InitVol" is not
Off.
<Range> :
0 to 100
Initial POS Select programme number.
Set this programme number, each time power is
switched on.
<Selection> :
Off/0 to 99 (Euro model)
·
Off: give priority to a last memory
Button lock Select local key conditions.
Set this condition, each time power is switched
on.
<Selection> :
Off/SETUPMENU/All
·
Off: altogether valid
·
SETUP: restrict F-key selection
(Tuning guide(menu) can not be selected.)
·
MENU: restrict F-key selection
(only Volume/Mute can be selected.)
·
All: altogether invalid.
Remote lock Select remote control key conditions.
Set this condition, each time power is switched
on.
<Selection> :
Off/SETUP/MENU
·
Off: altogether valid
·
SETUP: only Setup menu is invalid
·
MENU: Picture/Sound/Setup menu are invalid
12 Hotel mode
35
TH-42PA50E / TH-42PE50B / TH-37PA50E / TH-37PE50B