EasyManua.ls Logo

Panasonic TH-42PS9UK - Initialization Pulse Adjust; Printed Circuit Board) Exchange

Panasonic TH-42PS9UK
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2. Initialization Pulse Adjust
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 170±5µ Sec.
Test point Volume Level
T2 TPSC1 (SC) VR6602 (SC) 170 ± Sec.
9.3. P.C.B. (Printed Circuit Board) exchange
9.3.1. Caution
1. To remove P.C.B., wait for 1 minute after power was off for discharge from electrolysis capacitors.
9.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B. Name Test Point Voltage Volume Remarks
P Board Vsus TPVSUS (SS) Vsus ± 1V R628 (P) *
Vdat P12-1, 5 (P) 70.2V ± 0.1V R665 (P)
PFC C446 (+) (-) (P) 396V ± 0.5V R443 (P)
SC Board Vad TPVAD (SC) -90V ± 1V VR6600 (SC)
SS Board Ve TPVE (SS) Ve ± 1V VR6000 (SS) *
D, J, DA Board White balance for NTSC, PAL, HD, PC and 625i signals
DA Board Set Market Select Number to correct destination by MS mode. (See chap. 10.1.4)
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
21
TH-42PS9UK

Table of Contents