EasyManua.ls Logo

Panasonic TH-42PX600U

Panasonic TH-42PX600U
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.6. Remove the P-Board
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the cable clampers to free the cable.
2. Disconnect the couplers (P2, P5, P9, P10, P11, P12, P23,
and P25).
3. Remove the screws (×7
) and remove the P-Board.
6.7. Remove the PA-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the couplers (PA1, PA2, PA5, PA10, PA31,
PA32, PA33 and PA40).
3. Disconnect the flexible cable (PA20).
4. Remove the screws (×4
) and remove the earth cable.
5. Remove the PA-Board.
6.8. Remove the tuner unit
1. Unlock the cable clampers to free the cable.
2. Disconnect the couplers (DG5, G51, GS52, PA40 and earth
cable).
3. Disconnect the flexible cables (DG3 and PA20).
4. Remove the screws (×4
) remove the tuner unit.
6.9. Remove the DT-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the couplers (HC06 and DT10).
3. Remove the screws (×5
) remove the DT-Board unit.
(Be careful the coupler (DT12-DG22) when remove the DT-
Board unit.)
11