97
English
Serial daisy chain position
Set the first and last terminals in the chain when the
SERIAL IN/OUT terminal of this unit is connected using
a daisy chain scheme.
[---]:
When controlling this unit alone with serial control,
or connecting at a position other than the first and
last terminals in a daisy chain
[Top]:
When connecting at the first terminal in a daisy
chain
[End]:
When connecting at the last terminal in a daisy
chain
Information timing
Set up the informing manner for no signal or
temperature rising.
During RS-232C controls:
Warning or error message sent from the display
automatically.
During LAN controls:
Acquire the warning or error message from the
display.
1
Select the item with .
Select the set point with
.
Information timing
No signal warning
No signal warning timing
Temperature warning
No signal error
No signal error timing
On
5min
On
10min
On
[No signal warning]
When set to [On], the display sends out the no signal
warning.
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range: 01 - 60, Interval: 1 minute)
[No signal error]
When set to [On], the display sends out the no signal
error.
[No signal error timing]
Set up the detecting time for no signal error.
(Range: 01 - 90, Interval: 1 minute)
●
The warning of [No signal warning] and the error
of [No signal error] are not sent when the no signal
state is detected through any of the following
functions:
[No signal power off], [HDMI1 power management],
[HDMI2 power management], [DVI-D power
management], [PC power management] (see page
82)
Setting Example:
[No signal warning timing]: 5 minutes
[No signal error timing]: 10 minutes
Note
●
The [No signal error timing] cannot be set shorter
than [No signal warning timing].
[Temperature warning]
When set to [On], the display sends out the warning
message.
Note
●
The USB input does not support the No-signal
items of [Information timing].
Power on screen delay
You can set the power-on delay time of the displays to
reduce the power load, when you press <Main Power
On / Off button> to turn on the multiple displays that are
set together.
Set each display’s setting individually.
[Off]:
The display will be turned on at the same time as
<Main Power On / Off button> is pressed.
[Auto]:
Sets the delay time automatically according to the
number set for [Display ID].
The delay time is determined by multiplying
[Display ID] × 0.3 seconds.
Example:
When [Display ID]is3→0.9seconds
1 to 30:
Set the power-on delay time (second).
After pressing <Main Power On / Off button>,
the display will be powered on with time delay
depending on this setting.