EasyManua.ls Logo

Panasonic UF-7300 - Poor Transmitted Copy Quality

Panasonic UF-7300
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
119
UF-7300/7200
UF-8300/8200
4.5.2. Poor Transmitted Copy Quality
START
Yes
Make a copy.
No
No
Yes
Is the printed copy normal?
Perform a transmission test
to a reference fax unit.
Is the LED lit?
Yes
Yes
No
Are CN (
SC, SDR
PCB)
and CN (CIS Assembly)
connected properly?
Connect them correctly.
Replace the LVPS.
Does nLEDON go Low
when the scan starts?
Check CN on the SC,
SDR PCB, and the CIS
harness.
Does the problem still
occur?
Replace the CIS
Assembly.
The receiving unit may be
defective.
1. Replace the Scanner Block.
2. Replace the
SC
PCB.
3. Replace the
SDR
PCB.
Replace the
SC
PCB.
Is the transmitted copy
normal?
No
Yes
No
No
and CN (FXB PCB).
2. Check the telephone line cable.
Replace if necessary.
Does poor transmitted copy
appear when transmitting to
a specific receiver?
Telephone line quality is poor.
END
Yes
Yes
Yes
Does
+5 VDC alive
on
the
SDR PCB?
1. Check CN (
SC
PCB),

Table of Contents

Other manuals for Panasonic UF-7300

Related product manuals