68
Postamble string setting
0-22 characters
(Default: None)
00-FF
16
Insert G1 string setting
0-22 characters
(Default: None)
00-FF
16
Insert G2 string setting
0-22 characters
(Default: None)
00-FF
16
Insert G3 string setting
0-22 characters
(Default: None)
00-FF
16
Insert G4 string setting
0-22 characters
(Default: None)
00-FF
16
FN1 substitution string setting
0-4 characters
00-FF
16
<SP>
20*
*
END
3-30 G1-G4 string position & Code ID position
Format of barcode data transmission:
Prefix
Code name
Preamble
Code ID
Code length
Code data
Code ID
Postamble
Suffix
Insert G1/G2/G3/G4 string position: The scanner offers 4 positions to insert strings among the symbol. In
case of the insertion position is greater than the length of the symbol, the insertion of string is not effective.
Code ID position: It is allowed to select different positions of code ID placement.
SETUP
Multiple-scan setting
Single-scan setting
Option bar code
Option
Alpha. value
Insert G1 string position
00-99
00-99
00*
*
Insert G2 string position
00-99
00-99