Digiplex DGP-848 - 21 - Programming Guide
Partition 2: Options
Bold = Default setting
* If the keypad is assigned to more than one partition, the feature must be enabled in all the keypad’s partitions.
Section [509]: Partition 2 Options
Option OFF ON
[1] Partition 2 arms & disarms with Partition 1 N Disabled N Enabled
[2] Switch to Stay Arming (if no delay zone opened) N Disabled N Enabled
[3] Partition 2 arms & disarms with Partition 3 N Disabled N Enabled
[4] Partition 2 arms & disarms with Partition 4 N Disabled N Enabled
[5] Timed Auto-Arming N Disabled N Enabled
[6] “No Movement” Auto-Arming N Disabled N Enabled
[7] Arming method for auto arming N Force Arming N Stay Arming
[8] Exit Delay termination N Disabled N Enabled
Section [510]: Partition 2 Options
Option OFF ON
[1] Panic 1 (keys [1] and [3]) N Disabled N Enabled
[2] Panic 2 (keys [4] and [6]) N Disabled N Enabled
[3] Panic 3 (keys [7] and [9]) N Disabled N Enabled
[4] Panic 1 alarm type N Report Only N Audible Alarm
[5] Panic 2 alarm type N Report Only N Audible Alarm
[6] Panic 3 alarm type N Report Only N Fire Alarm
[7] Report Disarming Options N Always report disarming N Report disarming only after alarm
[8] Always Force Arm When Regular Arming N Disabled N Enabled
Section [511]: Partition 2 Options
Option OFF ON
[1] Bell Squawk upon Disarming N Disabled N Enabled
[2] Bell Squawk upon Arming N Disabled N Enabled
[3] Bell Squawk upon Auto-Arming N Disabled N Enabled
[4] Bell Squawk during Exit Delay N Disabled N Enabled
[5] Bell Squawk during Entry Delay N Disabled N Enabled
[6] Bell Squawk upon Remote Arming/Disarming N Disabled N Enabled
[7] Ring Back: bell squawk if disarmed after alarm N Disabled N Enabled
[8] Ring Back: keypad beeps if disarmed after alarm N Disabled N Enabled
Section [512]*: Partition 2 Options
Option OFF ON
[1] One-Touch Regular Arming N Disabled N Enabled
[2] One-Touch Stay Arming N Disabled N Enabled
[3] One-Touch Instant Arming N Disabled N Enabled
[4] One-Touch Force Arming N Disabled N Enabled
[5] One-Touch Stay or Instant Disarming N Disabled N Enabled
[6] One-Touch Bypass Programming N Disabled N Enabled
[7] One-Touch Event Display N Disabled N Enabled
[8] No Exit Delay when arming with remote control N Disabled N Enabled