EasyManua.ls Logo

Paradox Digiplex DGP-848 - System Options; Section [500]: System Options; Section [501]: System Options

Paradox Digiplex DGP-848
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digiplex DGP-848 - 18 - Programming Guide
System Options
Bold = Default setting
[465] Zone 15
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[489] Zone 39
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[466] Zone 16
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[490] Zone 40
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[467] Zone 17
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[491] Zone 41
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[468] Zone 18
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[492] Zone 42
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[469] Zone 19
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[493] Zone 43
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[470] Zone 20
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[494] Zone 44
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[471] Zone 21
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[495] Zone 45
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[472] Zone 22
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[496] Zone 46
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[473] Zone 23
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[497] Zone 47
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[474] Zone 24
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
[498] Zone 48
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
Section [500]: System Options
Option OFF ON
[1] Partition 1 N Disabled N Enabled
[2] Partition 2 N Disabled N Enabled
[3] Partition 3 N Disabled N Enabled
[4] Partition 4 N Disabled N Enabled
[5] Bell/Siren Output in Partition 1 N Disabled N Enabled
[6] Bell/Siren Output in Partition 2 N Disabled N Enabled
[7] Bell/Siren Output in Partition 3 N Disabled N Enabled
[8] Bell/Siren Output in Partition 4 N Disabled N Enabled
Section [501]: System Options
Option OFF ON
[1]&[2]
N see table
N see table
N see table
N see table
[3]
Generate Supervision Failure if detected on a
Bypassed Wireless Zone
N Yes N No
[4]
Restrict Arming on Wireless Transmitter
Supervision Failure
N Disabled N Enabled
Wireless Transmitter Supervision Options
[1] [2]
OFF OFF Disabled (default)
ON OFF When disarmed: GENERATES TROUBLE ONLY
When armed: Follows Zone Alarm Types (page 5)
OFF ON GENERATES TROUBLE ONLY (armed or disarmed)
ON ON When disarmed: GENERATES AUDIBLE ALARM
When armed: Follows Zone Alarm Types (page 5)

Other manuals for Paradox Digiplex DGP-848

Related product manuals