DigiplexNE DGP-NE96 - 21 - Programming Guide
NOTE 1 : 000 = Occurs in all partitions enabled in the system (see section [3 03 1] ).
001 = Pa rt it io n 1 00 3 = Partition 3 00 5 = Partition 5 007 = Partition 7 255 = Occurs in at least one partition enabled in the system.
002 = Pa rt it io n 2 00 4 = Partition 4 00 6 = Partition 6 008 = Partition 8
NOTE 2: Th e TL M tr oub le e ven t ca n o nly b e u sed wit h th e Dig iplex NE cont ro l pa nel models t ha t ha ve two d ialer s.
NOTE 3: This event cannot be used for a module’s PGM programming.
: Utility Keys:
06 7 S pecial Statu s N/A Fail to Communica te 1 113 113
Fail to Communica te 2 114 114
Fail to Communica te 3 115 115
Fail to Communica te 4 116 116
Fa il to Co mmun icate with PC 117 117
Fu ture Use 118 118
Fu ture Use 119 119
Mod ule Tam per Troub le 120 12 0
Module ROM error 121 121
Module TLM error 122 122
Mo dule Failure to Comm un icate 1 23 12 3
Modu le Printe r Trou ble 1 24 12 4
Module AC Failure 125 125
Modu le Ba tte ry Trou ble 1 26 12 6
Mo dule Au xiliar y Fa ilure 1 27 12 7
Missing Keypad 128 128
Missing Module 129 129
Future Use 130 to 132 130 to 13 2
Global Bus Failure 133 133
Bus Overload 134 134
B us Fa il to Co mmun icate 1 35 13 5
07 0 Clock N/A Ho ur Minu tes
Ut ility Key 1 Keys [1] and [2]
Ut ility Key 2 Keys [4] and [5]
Ut ility Key 3 Keys [7] and [8]
Utility Key 4 LCD or LED: [CLEAR] and [0 ]
Graf ica: [
*
] an d [0 ]
Ut ility Key 5 Keys [2] and [3]
Ut ility Key 6 Keys [5] and [6]
Ut ility Key 7 Keys [8] and [9]
Utility Key 8 LCD or LED: [0] and [EN TE R]
Graf ica: [0] and [#]
Event Group Event Feature Group Feature Start # End #