12 Programming Guide
System Programming
System Timers
[749] ____/____/____ (000 to 255) x 15 minutes Partition 1 no movement (default 000)
[750] ____/____/____ (000 to 255) x 15 minutes Partition 2 no movement (default 000)
Section Data Description
[761] ____/____:____/___ HH: MM Auto-arm on time Partition 1 (default 00:00)
[762] ____/____:____/____ HH: MM Auto-arm on time Partition 2 (default 00:00)
[700] General System Options
Option OFF ON
[3]
Audible trouble warning (except AC failure)
N Disabled N Enabled
[4]
Audible trouble warning on AC failure
N Disabled N Enabled
[6]
Exit delay termination
N Disabled N Enabled
[7]
Tamper supervision on the bus module
N Disabled N Enabled
[702] Panic Options
Option OFF ON
[1]
Panic 1
Disabled N Enabled
[2]
Panic 2
Disabled N Enabled
[3]
Panic 3
Disabled N Enabled
[4]
Panic 1: Report only or audible alarm
Report only N Audible
[5]
Panic 2: Report only or audible alarm
Report only N Audible
[6]
Panic 3: Report only or audible alarm
Report only N Audible
[703] Arming/Disarming Options 1
Option OFF ON
[5]
Restrict arming on battery failure
Disabled N Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module)
Disabled N Enabled
[8]
Calling the VDMP3
N Disabled Enabled
[704] Arming/Disarming Options 2
Option OFF ON
[1]
Regular arming switches to force arming
N Disabled Enabled
[2]
Stay arming switches to stay force arming
N Disabled Enabled
[3]
Sleep arming switches to sleep force arming
N Disabled Enabled
Section Data Description
[710] ____/____/____ (000 to 255) seconds Entry delay 1 (default 045)
[711] ____/____/____ (000 to 255) seconds Entry delay 2 (default 045)
[712] ____/____/____ (000 to 015) Auto zone shutdown counter (default 005)
[713] ____/____/____ (000 to 255) seconds Intellizone delay (default 048)
[714] ____/____/____ (000 to 255) minutes Recycle alarm delay (default 000)
[715] ____/____/____ (000 to 255) Recycle alarm counter (default 000)
[718] N/A N/A N/A
[719] ____/____/____ (000 to 255) days Closing delinquency delay (default 000)
[720] ____/____/____ (000 to 255) seconds For StayD: Flex-Instant delay (default 015)
[721] ____/____/____ (000 to 255) seconds For StayD: Re-arm delay (default 005)
Section Data Description
See Quick Menus on page 39