EasyManuals Logo

Paradox Esprit E55 User Manual

Paradox Esprit E55
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
20 Programming Guide
Event Description
Event Group # Sub-group #
00 = Zone OK 01 to 32 = Zone number
99 = Any zone number01 = Zone open
02 = Partition status 00 to 01= N/A
02 = Silent alarm
03 = Buzzer alarm
04 = Steady alarm
05 = Pulsed alarm
06 = Strobe
07 = Alarm stopped
08 = Squawk ON (Partition 1 only)
09 = Squawk OFF (Partition 1 only)
10 = Ground start (Partition 1 only)
11 = Disarm partition
12 = Arm partition
13 = Entry delay started
14 = Exit delay started
15 = Pre-alarm delay
99 = Any partition status event
03 = Bell status (Partition 1 only) 00 = Bell OFF
01 = Bell ON
02 = Bell squawk arm
03 = Bell squawk disarm
99 = Any bell status event
06 = Non-reportable event 00 = Telephone line trouble
01 = [
ENTER] / [CLEAR] / [ ] key was pressed (Partition 1 only)
02 = N/A
03 = Arm in stay mode
04 = Arm in sleep mode
05 = Arm in force mode
06 = Full arm when armed in stay mode
07 = PC fail to communicate (Partition 1 only)
08 = Utility Key 1 pressed (keys [1] and [2]) (Partition 1 only)
09 = Utility Key 2 pressed (keys [4] and [5]) (Partition 1 only)
10 = Utility Key 3 pressed (keys [7] and [8]) (Partition 1 only)
11 = Utility Key 4 pressed (keys [2] and [3]) (Partition 1 only)
12 = Utility Key 5 pressed (keys [5] and [6]) (Partition 1 only)
13 = Utility Key 6 pressed (keys [8] and [9]) (Partition 1 only)
14 = Tamper generated alarm
15 = Supervision loss generated alarm
16 = N/A
17 = N/A
18 = N/A
19 = N/A
20 = Full arm when armed in sleep mode
21 = Firmware upgrade (Partition 1 only) (non-PGM event)
22 = No SIM card on GSM module
23 = StayD mode activated
24 = StayD mode deactivated
25 = IP Registration Status (E65 panels only)
26 = GPRS Registration Status (E65 panels only)
99 = Any non-reportable event
14 = Bypass programming 01 to 32 = User number
99 = Any user number15 = User code activated output (Partition 1 only)
16 = N/A 01 to 32 = Zone number
99 = Any zone number17 = Delay zone alarm transmission
18 to 23 = N/A
24 = Fire Delay started 01 to 32 = Zone number
99 = Any zone number
25 = N/A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit E55 and is the answer not in the manual?

Paradox Esprit E55 Specifications

General IconGeneral
BrandParadox
ModelEsprit E55
CategorySecurity System
LanguageEnglish

Related product manuals