EasyManuals Logo

Paradox Esprit E55 User Manual

Paradox Esprit E55
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
24 Programming Guide
Programmable Output Delays & Recognition
System Report Codes
Entering Report Codes
Ademco Slow, Silent Knight, SESCOA, and Ademco Express Formats:
Enter the desired 2-digit hex value (00-FF).
Ademco “Programmable” Format:
Enter the desired 2-digit hex values from the “Ademco Report Code List - Programmable” (see page 26). Also Note that entering FF will
set the report code to the “Automatic Report Code List” (see page 28).
Ademco “All Codes” Format:
The control panel automatically generates report codes from the “Ademco Report Code List - All Codes” (see page 26).
Refer to Decimal and Hexadecimal Values on page 3.
Clear System Report Codes
Reset System Report Codes
Special Arming Report Codes
(Default = FF)
Section Data Default = 005
[281] PGM 1: (E55/E65 onboard) ___/___/___ (000 to 255 x 1 sec./mins.)
[282] PGM 2: (E65 onboard) ___/___/___ (000 to 255 x 1 sec./mins.)
[283] PGM 3: (E65 onboard) ___/___/___ (000 to 255 x 1 sec./mins.)
[286] PGM 6: (ZX8 ID =+1) ___/___/___ (000 to 255 x 1 sec./mins.)
[287] PGM 7: (ZX8 ID =+9) ___/___/___ (000 to 255 x 1 sec./mins.)
[288] PGM 8: (ZX8 ID =+17) ___/___/___ (000 to 255 x 1 sec./mins.)
[289] PGM 9: (PGM4 output 1) ___/___/___ (000 to 255 x 1 sec./mins.)
[290] PGM 10: (PGM4 output 2) ___/___/___ (000 to 255 x 1 sec./mins.)
[291] PGM 11: (PGM4 output 3) ___/___/___ (000 to 255 x 1 sec./mins.)
[292] PGM 12: (PGM4 output 4) ___/___/___ (000 to 255 x 1 sec./mins.)
[966] Clear Report Codes
Option OFF ON
[3]
Clear arm/disarm/alarm report codes*
N Disabled N Enabled
[4]
Clear trouble report codes*
N Disabled N Enabled
[5]
Clear system special report codes*
N Disabled N Enabled
* Press [
ENTER] to reset the respective set of report codes to default before exiting the section.
[967] Reset Report Codes
Option OFF ON
[3]
Reset arm/disarm/alarm report codes to default*
N Disabled N Enabled
[4]
Reset trouble report codes to default*
N Disabled N Enabled
[5]
Reset system special report codes to default*
N Disabled N Enabled
* Enable all options you want to reset to default. Press [
ENTER] to reset the respective set of report codes to
default before exiting the section.
Section Data Description Section Data Description
[860] _____/_____ Auto-arming [861] _____/_____ Quick arming
_____/_____ Late to close _____/_____ Arming via PC
_____/_____ No movement _____/_____ Arming with keyswitch
_____/_____ Partial arming _____/_____ N/A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit E55 and is the answer not in the manual?

Paradox Esprit E55 Specifications

General IconGeneral
BrandParadox
ModelEsprit E55
CategorySecurity System
LanguageEnglish

Related product manuals