Esprit E55 / E65 29
Zone shutdown (##) 1 57A - Zone bypass
Zone tampered (##) 1 144 - Sensor tamper
Zone tamper restore (##) 3 144 - Sensor tamper restore
AC failure 1 3A1 - AC loss
Battery failure 1 3A9 - Battery test failure
Auxiliary supply trouble 1 3AA - System trouble
Bell output current limit 1 321 - Bell 1
Bell absent 1 321 - Bell 1
Clock lost 1 626 - Time/date inaccurate
Fire loop trouble 1 373 - Fire trouble
Communication fail 1 354 - Communication fail
RF jamming 1 344 - RF receiver jam detection
TLM trouble restore 3 351 - Telco 1 fault restore
AC failure restore 3 3A1 - AC loss restore
Battery failure restore 3 3A9 - Battery test restore
Auxiliary supply trouble restore 3 3AA - System trouble restore
Bell output current limit restore 3 321 - Bell 1 restore
Bell absent restore 3 321 - Bell 1 restore
Clock programmed 3 625 - Time/date reset
Fire loop trouble restore 3 373 - Fire trouble restore
Fail to communicate with monitoring station 3 354 - Fail to communicate
RF jamming 3 344 - RF receiver jam detection
Combus fault 1 333 - Expansion module failure
Module tamper 1 341 - Expansion module tamper
Bus fault restore 3 333 - Expansion module failure restore
Module tamper restore 3 341 - Expansion module tamper restore
Cold start 1 3A8 - System shutdown
Test report engaged 1 6A2 - Periodic test report
PC software communication finished 1 412 - Successful - download access
Installer on site 1 627 - Program mode entry
Installer programming finished 1 628 - Program mode exit
Maintenance in 1 627 - Program mode entry
Maintenance out 1 628 - Program mode exit
Closing delinquency 1 654 - System inactivity
Module AC fail 1 342 - AC failure on module
Module AC fail restore 3 342 - AC restored on module
Module battery fail 1 338 - Battery failure on module
Module battery fail restore 3 338 - Battery failure on module
RF Module low battery 1 384 - RF transmitter low battery
RF Module battery restore 3 384 - RF transmitter battery restore
RF Module supervision trouble 1 381 - Loss of supervision - RF
RF Module supervision restore 3 381 - Supervision restore - RF
RF Module supervision lost 1 381 - Loss of supervision- RF
RF Module supervision restore 3 381 - Loss of supervision- RF restore
RF Module tamper 1 145 - Expansion module tamper
RF Module tamper restore 3 145 - Expansion module tamper restore
Paramedic alarm 1 1AA - Medical
Zone forced 1 57A - Zone forced
Zone included 3 57A - Zone included
System Event Default Contact ID Report Code

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit E55 and is the answer not in the manual?

Paradox Esprit E55 Specifications

General IconGeneral
BrandParadox
ModelEsprit E55
CategorySecurity System
LanguageEnglish

Related product manuals