Miscellaneous System Options
Unlock Panel Serial Ports
Enter section [300] to unlock your MG5050+’s panel serial ports for use with third-party devices using a TM70/TM50 Touch keypad or K32LCD+ keypad. For a step-
by-step procedure, refer to the Insite Gold Installer Menu Guide.
System Timers
Use the following section to program system timers on your MG5050+ control panel. Use worksheet 28 to record your settings.
Keypad Lockout
Use the following section to program keypad lockout settings for your MG5050+ control panel. Use worksheet 29 to record your settings.
NOTE: For EN 50131, the keypad lockout value must be set between three and ten attempts. The minimum delay to lock must be two minutes.
Programming the Daylight Savings Feature
Use the following section to program Daylight Savings Time on your MG5050+ control panel. Use worksheet 30 to record your settings.
Table 27: Description of section [708]
Option Description OFF ON
Section [708]
EN50131
OPTIONS
1 Enter code to view trouble One-touch
Enter code
2 Enter code to view alarm in memory/event list One-touch
Enter code
3 Trouble latch Disabled
Enabled
4 Bell squawk on Installer in Disabled
Enabled
5 Acknowledge trouble(s) before arming Disabled
Enabled
6 Do not arm if zone opens during exit delay Disabled
Enabled
7 Disable ‘Bypass and Arm Disabled
Enabled
8 Future use
= Default
Worksheet 28: System Timers
Section Data Description Section Data Description
[710] ___/___/___ 000 to 255 seconds Entry delay 1* (default: 045) [718] ___/___/___ 000 to 255 seconds
Remote panic disarm lock delay
(default: 000)
[711] ___/___/___ 000 to 255 seconds Entry delay 2* (default: 045) [719] ___/___/___ 000 to 255 days
Closing delinquency delay
(default: 000)
[712] ___/___/___ 000 to 015
Auto-zone shutdown counter
(default: 005) [720] ___/___/___ 000 to 255 seconds Flex-instant delay (default: 015)
[713] ___/___/___ 000 to 255 seconds Intellizone delay (default: 048) [721] ___/___/___ 000 to 255 seconds
For StayD: re-arm delay
(default: 005)
[714] ___/___/___ 000 to 255 minutes Recycle alarm delay (default: 000) [722] ___/___/___ 000 to 255 times
Auto trouble shutdown**
(default:000)
[715] ___/___/___ 000 to 255
Recycle alarm counter
(default: 000) [723] ___/___/___ 000 to 255 seconds
Panic shutdown**
(default:000)
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10
Worksheet 29: Keypad Lockout
Section Data Description Default
[716] ___/___/___ 000 to 255 minutes Keypad lockout delay 000
[717] ___/___/___ 000 to 255 attempts before locking Keypad lockout counter 000
Table 28: Description of section [730]
Section Option Description OFF ON
[730]
1Daylight savings Disabled
Enabled
= Default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox MG5050+ and is the answer not in the manual?

Paradox MG5050+ Specifications

General IconGeneral
Partitions2
PGMs16
Wireless Zones32
StayD ModeYes
Number of Zones32
WirelessYes
Remote ControlYes, via remote controls and app
Power Supply16.5 V AC
Battery Backup7Ah
Zones32 (8 on-board)

Related product manuals