System Trouble Report Codes
Use worksheet 41 to record your settings for system
trouble report codes.
System Trouble Restore Codes
Use worksheet 42 to record your settings for system
trouble restore codes.
System Special Report Codes
Use worksheet 43 to record your settings for system
special report codes.
NOTE: For report code formatting instructions, see
Entering Report Codes on page 44.
Installer Function Keys
Worksheet 41: Special Trouble Report Codes
Section Data Description Section Data Description Section Data Description
[865]
___/___ -
[866]
___/___ Bell output overload
[867]
___/___ Fail to communicate
___/___ AC failure ___/___ Bell output disconnected ___/___ RF jamming
___/___ Battery failure ___/___ Timer loss ___/___ Module lost
___/___ Auxiliary supply ___/___ Fire loop trouble ___/___ Module tamper
[868]
___/___ Module power fail
[869]
___/___
Wireless module
supervision lost
Default: FF
___/___ Module low/no battery* ___/___ Wireless module tamper
___/___ Wireless zone low battery ___/___ Remote low battery
___/___ Wireless zone supervision lost ___/___ -
Worksheet 42: System Trouble Restore Codes
Section Data Description Section Data Description Section Data Description
[870]
___/___ TLM
[871]
___/___ Bell output overload
[872]
___/___ Fail to communicate
___/___ AC failure ___/___ Bell output disconnect ___/___ RF jamming
___/___ Battery failure ___/___ Timer loss ___/___ Module lost
___/___ Auxiliary supply ___/___ Fire loop trouble ___/___ Module tamper
[873]
___/___ Module power fail
[874]
___/___
Wireless module
supervision lost*
Default: FF
___/___ Module low/no battery* ___/___ Wireless module tamper
___/___ Wireless zone low battery ___/___ Remote low battery
___/___ Wireless zone supervision lost ___/___ -
Worksheet 43: System Special Report Codes
Section Data Description Section Data Description Section Data Description
[875]
___/___ Cold start
[876]
___/___ Installer in
[877]
___/___ -
___/___ Test report ___/___ Installer out ___/___ -
___/___ - ___/___ Closing delinquency ___/___ -
___/___ Software out ___/___ - ___/___ Fail to arm
Default: FF
Table 39: Description of installer functions for MG5050+ keypads
Function Action Description
Test report
ENTER + installer code + ENTER Sends the Test Report report code programmed in section [875], to the monitoring station.
Cancel communication
ENTER + installer code + STAY
Cancels all communication with the BabyWare software or with the monitoring station, until the next
reportable event.
Answer BabyWare
software
ENTER + installer code + SLEEP
Will force the console to answer an incoming call from the monitoring station, which is using the
BabyWare software.
Call BabyWare
software
ENTER + installer code + BYP
Will dial the PC telephone number programmed in section [915], thereby initiating communication
with a computer using the BabyWare software.
Installer test mode
ENTER + installer code + TBL
This mode allows to perform walk tests, where the siren will squawk to indicate opened zones.
To exit, press
TBL.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox MG5050+ and is the answer not in the manual?

Paradox MG5050+ Specifications

General IconGeneral
Partitions2
PGMs16
Wireless Zones32
StayD ModeYes
Number of Zones32
WirelessYes
Remote ControlYes, via remote controls and app
Power Supply16.5 V AC
Battery Backup7Ah
Zones32 (8 on-board)