Rate Target
Segment Per Hour Temp. Hold
1 250 750 00.00
2 900 1425 00.30
3 9999 1050 00.00
4 150 750 00.00
Glass Slumping Firing Schedule
Stained glass,
1
8
", 2 fused layers, 12" circular pieces,
slumped intoa bowl.Set thealarm to500° F.When thealarm
sounds,closethelidfromventingpositionandinsertpeephole
plugs. Set the alarm again, this time to 1150° F. When it
sounds,checktheglassthrough thepeephole. Whentheglass
slumps into the bowl, write down the temperature and hold
time for future firings, and press 9, ENTER (Skip Segment).
This will advance you to segment 3, a flash cooling seg
-
ment. Lift the kiln lid slightly or open the door ajar until the
temperature drops to 1050° F. Then close the door/lid. The
kiln will cool slowly through the annealing range.Then it will
turn off and cool to room temperature.
Rate Target
Segment Per Hour Temp. Hold
1 250 750 00.00
2 900 1250 00.30
3 9999 1050 00.00
4 150 750 00.00
16 Segment Firing (16-S)
16 segment firing combines Ramp-Hold user programs 5
and6 intoonecontinuous firing.Youcan useall16 segments,
oronlyafewsegmentsfromeachprogram.Program5willfire
first, then program 6.
1 Press ENTER, then 4. USEr will appear, alternating
with the last user program entered.
2 Press 5 (user program 5), then ENTER. Using
Ramp-Holdinstructions, enterthe valuesfor allseg
-
ments needed in program 5.
3 IdLE andtemperaturewilldisplayafterprogram5is
entered. From IdLE , press ENTER, then 4.
4 USEr will appear, alternating with 5. Press 6(user
program 6), then press ENTER. As before with pro
-
gram 5, enter the values for all segments needed in
program 6.
5 IdLE will appear after program 6 is entered. Press
ENTER,thenPROGRAM REVIEW. Makesure all val
-
ues for user program 6 are correct. After reviewing
the program, IdLE will appear.
6 From IdLE , press ENTER, then 4. USEr will ap
-
pear, alternating with 6. Press 5, then ENTER.
7 Press STOP. CPL willappear, then IdLE and tem
-
perature. Program 5 is now selected in Ramp-Hold.
8 From IdLE , press 0repeatedly until 16-S appears.
Press ENTER.
9 OFF or ON willappear. Press1to change OFF to
ON . On will appear. Press ENTER. CPL will ap
-
pear, then IdLE .
10 Begin firing by pressing ENTER twice.
16-S appearsunderOPTIONS onlyafteruserprogram
5 has been selected in Ramp-Hold.
When you use Program Review for a 16 segment firing,
user program 5 will appear. Then 16-S , On , to con-
firm that your program is the 16 segment. However, the
valuesforuserprogram6willnotappearinProgramRe-
view.
Additional Features
Selecting °F or °C (CHG°)
Thecontrolleroperatesinyourchoiceof°For°Ctempera
-
ture. In°C display,a lighteddot appears in the lower right. In
°F, it disappears. To switch from °F to °C or vice versa:
1 From IdLE , press ENTER.
2 Press 0repeatedly until CHG° appears.
3 Press ENTER. °F or °C will appear.
4 To change, press 1.
5 Press ENTER. CPL willappear, meaningthe change
has been completed.
°F/°C Temperature Conversion Formula
Below are formulas for converting temperture between °F
and °C. Converting a firing rate requires a different formula
than firing temperature:
Firing Temperature
(i.e. “Fire to 1600°F.” 1600°F = 871°C)
(°C x 1.8) +32 = °F
(°F - 32) ÷ 1.8 = °C
Firing Rate and Temperature Change
(i.e. “Fire at 200°F per hour” or “Fire 200°F hotter.”
200°F = 111°C)
°C x 1.8 = °F
°F ÷ 1.8 = °C
12