24
DTC 1000 Ramp-Hold Quick Reference
After you press the keys in the left column, the message to the right will appear. If alarm sounds during a firing, press ENTER.
KEYS TO PRESS DISPLAY
STORE A USER PROGRAM, THEN FIRE; NO DELAY FIRE.
Apply power to kiln ErrP
ENTER IdLE
ENTER ----
4 USEr / 1 etc.
Select program 1 through 6 1 etc. (displays # entered)
ENTER SEG
Number of segments needed 1 etc. (displays # entered)
ENTER rA 1
Temperature change per hour 0200 etc. (displays temp.)
ENTER °F1
Final temperature, segment 1 2000 etc. (displays temp.)
ENTER HLd1
Hold time (if any) 00.00 (or hold time)
Repeat for number of segments desired.
ENTER ALAr (Alarm temperature)
Alarm temperature (OFF: 9999) 2000 etc. (displays temp.)
ENTER CPL IdLE and flashing temperature
ENTER ----
ENTER -On-
Kiln is now firing.
SELECT AND FIRE A STORED USER PROGRAM; NO DELAY FIRE.
Apply power to kiln ErrP
ENTER IdLE
ENTER ----
4 USEr / 1 etc. (Select program)
1 through 6 1 etc. (displays # entered)
ENTER SEG
STOP CPL IdLE and flashing temperature
ENTER ----
ENTER -On-
Kiln is now firing. (See separate Program Review instructions.)