EasyManua.ls Logo

Parker 590C - Short Circuit Rating; Field Wiring Temperature Rating; Operating Ambient Temperature; Field Wiring Terminal Markings

Parker 590C
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B-8 Certification 590 Series DC Digital Drive
Short Circuit Rating
These products are suitable for use on a circuit capable of delivering not more than (the value shown in Table 12-2) RMS Symmetrical Amperes, 500V
maximum.
Output Ratings Short Circuit Rating
A kW Hp RMS Symmetrical Amperes
35 15 20 5,000
70 30 40 5,000
110 45 60 10,000
150 60 80 10,000
180 75 100 10,000
270 110 150 10,000
Table B- 2 Short Circuit Ratings
Field Wiring Temperature Rating
Use 75°C copper conductors only.
Operating Ambient Temperature
For the operating ambient temperature range, refer to Appendix E: “Technical Specifications”.
Field Wiring Terminal Markings
For the correct field wiring connections that are to be made to each terminal, refer to Chapter 3: “Installing the Drive” - Electrical Installation.
Power and Control Field Wiring Terminals
For the correct tightening torque value, refer to Appendix E: “Technical Specifications”.

Table of Contents