7-6 Trips and Fault Finding 590 Series DC Digital Drive
Hexadecimal Representation of Trips
The LAST ALARM, HEALTH WORD, HEALTH STORE and ALARM HISTORY parameters use a four digit hexadecimal number to identify
individual trips. Each trip has a unique corresponding number as shown below.
Trip Codes : LAST ALARM only
14
AUTOTUNE ERROR F
0
0 1
14
AUTOTUNE ABORTED
F
0
0 2
14
SEQ PRE READY F
0
0 3
14
REMOTE TRIP F
0
0 6
14
SEQUENCING F
0
0 9
14
COMMS TIMEOUT F
0
1 0
14
CALIBRATION TRIP F
3
0 0
14
AUX SUPPLY F
F
0 3
LAST ALARM, HEALTH WORD and HEALTH STORE
Trip Trip Code
First Digit
Digit Digit Last Digit
NO ACTIVE ALARMS
0 OVERSPEED 1
1 MISSING PULSE 2
2 FIELD OVER I 4
3 HEATSINK TRIP 8
4 THERMISTOR 1
5 OVER VOLTS (VA) 2
6 SPD FEEDBACK 4
7 ENCODER FAILED 8
8 FIELD FAILED 1
9 3 PHASE FAILED 2
10 PHASE LOCK 4
11 5703 RCV ERROR 8
12 STALL TRIP 1
13 OVER I TRIP 2
14
OTHER •
4
15 ACCTS FAILED 8
• For the LAST ALARM parameter, replace OTHER with trip codes opposite.