T'ECHNICAL
B1JLLETIN
PARKER
COMPUMOTOR
No. 125
PRODUCT:
LE
Drive
DESCRIPTION:
Temperature
Specifications
SOFTWARE
AFFECTED:
n/a
NEXT
SCHEDULED
RELEASE:
n/a
July
12,
1988
Recently
it
was
discovered
that
the
temperature
specification
for
the
LE
Dri.ve
in
both
the
manual
and
our
catalog
was
incorrect.
The manual
and
catalog
specify
a 50°C
ambient
operating
temperature.
The
actual
ambient
operating
temperature
should
be
40°C.
If
it:
is
not
run
at
this
temperature
fan
cooling
may
be
necessary
or
the
drive
will
fault
due
to
overtemperature.
PIN:
88-006277-09
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com