B13
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
A
B
C
D
E
F
G
H
J
K
L
M
Catalog 0700P-5/USA
Programming Information
Set Control Signal
The unit is factory set for 0-10 V control signal. If 4-20 mA
control signal is required, change parameter 4.
or
or
Parameter Number 4 Set Control Signal in Volts or Milliamps
Step 1 2 3 4 5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal Flashing Decimal Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 4.
Displays current
parameter value.
1 = V
0 = mA
Edits parameter.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
or
or
Parameter Number 6 Set Output Signal
Step 1 2 3 4 5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(Value 0, 1 or 2) Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 6.
Displays current
parameter value.
1 = m factory
default for P3H
with analog
options
Edits parameter.
0 = digital
(NPN or PNP)
1 = analog 0..10V
2 = analog 4..20 mA
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
“P3HPA” / “P3KNA” Series
Electronic Proportional Regulators