Programming Information
Preset Minimum Pressure
If there is a need for a pre-set minimum pressure, use
parameter 18. (Note: preset pressure is affected by % P19.)
Set Pressure Scale
Units with NPT port threads are supplied with a factory set
PSI pressure scale. Use parameter 14 to change scale to bar.
or
or
Parameter Number 14 Set Pressure Scale in PSI or bar
Step 1 2 3 4 5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal Flashing Decimal Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 14.
Displays current
parameter value.
1 = PSI
0 = bar
Edits parameter.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
or
or
Parameter Number 18 Set Minimum Preset Pressure
Step 1 2 3 4 5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(value between
0 and 200)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 18.
Displays current
parameter value.
Incremental
value is:
2 bar unit:
x 2 mbar x % P19
10 bar unit:
x 10 mbar x % P19
Edits parameter.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
“P3HPA” / “P3KNA” Series