Loading...
B18
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
A
B
C
D
E
F
G
H
J
K
L
M
Catalog 0700P-5/USA
Programming Information
Proportional Effect
Sets the speed at which the regulator adjusts either filling or
exhausting. The displayed value has a range between 5
(fastest regulation) and 100 (slowest regulation).
or
Parameter Number 39 Displays Current Software Version
Step 1 2 3
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Description
Accesses
changeable
parameters.
Accesses
parameter no. 39.
Displays current
parameter value.
XXX = current
software version
Parameter Number 21 Set Proportional Effect (P20 Must be Set to 0)
Step 1 2 3 4 5
Press
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal
(value between
5 and 100)
Flashing
Description
Accesses
changeable
parameters.
Accesses
parameter no. 21.
Displays current
parameter value.
Edits parameter.
5 = fastest
regulation
100 = slowest
regulation.
Accepts and
saves new
parameter
setting.
Sequences to
next parameter.
or
or
“P3HPA” / “P3KNA” Series
Electronic Proportional Regulators