5.8.2 Analog monitor output mode(0x2220) setting
The output range of analog monitor is -10~+10V. With set value of 1, only the absolute
value (positive value) of the output value is displayed.
Figure 36. Analog Monitor Output Setting
5.8.3 Analog monitor channel 1 setting (0x2221)
You can set the monitoring variables to output through the monitor output channel 1.
Set Value
Displayed Items
Unit
0
Speed feedback
rpm
1
Speed command
rpm
2
Speed error
rpm
3
Torque feedback
%
4
Torque command
%
5
Position error
pulse
6
accumulated operation overload rate
%
7
DC Link voltage
V
8
accumulated regeneration overload rate
%
9
encoder single-turn data
pulse
10
Inertia ratio
%
11
Full-Closed position error (Reserved)
UU
12
drive temperature 1
°C
13
drive temperature2
°C
14
encoder temperature (Reserved)
°C
15
Hall sensor signal
16
phase U current
A
17
phase V current
A
18
phase W current
A