Digital Pump Control Module
Series PQDXXA-Z10
Installation and Setup Manual
Bulletin HY30-3255-INST/UK
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Pump & Motor Division Europe
Chemnitz, Germany
Terms for the oscilloscope- and monitor view:
All Parameters are displayed with a resolution
of 0,01. Please mind the units.
Parameters shown in the Oscilloscope are
sampled with 1 ms. The solenoid current has
a lower sampling rate. Please take the sole-
noid display only for informational purpose,
but do not take these values for quantitative
validation.
Do not start up a pump or hydraulic system
before loading the correct control program
for the particular pump size to the attached
module. Damage of the pump or components
connected to it can be the result.
Displacement Control:
WQ Displacement command in %
XQ Displacement actual value in %
UQ Correcting variable displacement control in %
XQ_R Displacement actual value in V or mA
IQ:A Current to solenoid A (displacement control valve) in mA
IQ:B Current to solenoid B (displacement control valve) in mA
Q:P P- Gain in % (Sum of offset CQ:FF and P:Gain)
Q:I I-Gain in %
Q:D D-Gain in %
Pressure Control:
WP Pressure command in bar
XP Pressure actual value in bar
XP_R Displacement actual value in V or mA
UP Correcting variable pressure control in %
(only if pressure transducer is installed)
IP Current to the pressure control valve in mA
P:P P-Gain in % (Sum of offset and P-Gain)
P:I I-Gain in %
P:D D-Gain in %
Horse Power Control
WL Horse Power command in %
PL:EXT Calculated out of the Command signal at PIN 29,
Parameter PL:PL is the maximum value
PL:INT Calculated from the input of Parameter PL:PL
XL Internal calculated maximum swivel angle in %