6.5. Important settings and diagnosis values
Settings- / diagnosis values
Max. Horse power and according horse power command
Calculation example for the external command:
A PV028 is driven with an input horse power of
15.0kW. Maximum horse power is 29.0kW (PL:PL
= 290). The voltage command input according to
this input horse power is 10.0V as shown in the
table left side.
Toadjustahorsepowerlimitof15.0kWacom-
mand voltage of.
15.0 kW / 29.0 kW x 10.0 V = 5.2 V
need to be set at PIN 29.
Size/Code max.
displacement
[[cm
3
/rev.]
Diagnosis signal
V
G max
[Volt
-0,5
]
LVDT signal
V
G max
[Volt
±0,25
]
Diagnosis signal
V
Gmin
[Volt]
LVDT signal
V
Gmin
[Volt
±0,25
]
PV016 16 10.0 6.34 0.0 7.5
PV020 20 10.0 6.06 0.0 7.5
PV023 23 10.0 5.87 0.0 7.5
PV028 28 10.0 5.50 0.0 7.5
PV032 32 10.0 6.40 0.0 7.5
PV040 40 10.0 5.70 0.0 7.5
PV046 46 10.0 5.43 0.0 7.5
PV063 63 10.0 7.12 0.0 9.0
PV080 80 10.0 6.48 0.0 9.0
PV092 92 10.0 6.10 0.0 9.0
PV140 140 10.0 5.24 0.0 9.0
PV180 180 10.0 3.83 0.0 9.0
PV270 270 10.0 4.06 0.0 9.0
PV360 360 10.0 4.06 0.0 9.0
Size/Code @350bar
@1500 rpm
[kW]
Command for
max. power
[V]
PV016 16.4 10.0
PV020 20.9 10.0
PV023 23.8 10.0
PV028 29.0 10.0
PV032 33.1 10.0
PV040 39.8 10.0
PV046 46.1 10.0
PV063 62.1 10.0
PV080 75.5 10.0
PV092 86.9 10.0
PV140 133.0 10.0
PV180 168.8 10.0
PV270 247.0 10.0
PV360 331.2 10.0