Start the engine with the pull starter ; pull firmly on the handle to do
this. If the engine does not start, pull the starter again.
After starting, push the choke
back in (in the right position).
NOTE
The procedure described in this section is suitable for both a cold
start and a warm start.
Turning the engine off
Run the appliance for a short while without load before you switch it
off so that the appliance can "aftercool".
Move the On/Off switch
to the "OFF" position.
Close the fuel tap
Starting the appliance
Switch on the water supply.
Start the engine with the trigger
open.
NOTE
You can remove the jet pipe
or the nozzle to make starting
easier.
Run the engine for 1 minute to warm it up.
Setting operating pressure and flow rate
The pressure and flow rate are fixed on this appliance and cannot be
changed.
Changing the nozzle
DANGER!
Before changing the nozzle, switch off the appliance and pull the
trigger
to depressurise the appliance.
Remove the nozzle
.
Fit the new nozzle
.
Use with a cleaning agent
WARNING!
Switch off the appliance before making any adjustments or carrying
out maintenance work.
WARNING!
Unsuitable cleaning agents can damage the appliance and the
object to be cleaned.
Use only recommended cleaning agents that are suitable for
high-pressure cleaners.
This appliance is suitable for operation with the cleaning agents
recommended by the manufacturer. The use of other cleaning agents
or chemicals can have a negative effect on the safety of the machine.
The recommended cleaning agents are primarily those that are suit-
able for use with high-pressure cleaners. These are available in
DIY and car accessory stores.
Hang the cleaning agent hose
in a container with cleaning agent.
Replace the high-pressure nozzle with low-pressure nozzle (black).
0° nozzle – red:
Extremely strong, precise jet. Cleans only a small area.
Do not use for cleaning wood!
15° nozzle – yellow:
Strong 15° jet for intensive cleaning of small surfaces.
Use only on surfaces and materials that can withstand high pressures.
25° nozzle – green:
25° jet for intensive cleaning of larger surfaces.
40° nozzle – white:
40° jet for cleaning large surfaces.
Chemicals nozzle – black:
Low-pressure nozzle for the application of cleaning agents.
Recommended cleaning methods
Dissolving dirt:
Spray the cleaning agent sparingly and leave to work for 1–5 minutes
but do not let it dry.
Removing dirt:
Rinse off the dissolved dirt using a high-pressure jet.
After using with a cleaning agent
Leave the appliance engine running and pull the trigger
for at least
1 minute to rinse itself.

Table of Contents

Other manuals for Parkside PHDB 4 B2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parkside PHDB 4 B2 and is the answer not in the manual?

Parkside PHDB 4 B2 Specifications

General IconGeneral
BrandParkside
ModelPHDB 4 B2
CategoryPressure Washer
LanguageEnglish

Related product manuals