MIC 1400
1/4 DIN MICROBASED CONTROLLER
OPERATORS
MANUAL
FORM 3665
EDITION 1
© OCT. 1995
PRICE $10.00
Brand
Question and Answer IconNeed help?

Do you have a question about the Partlow MIC 1400 and is the answer not in the manual?

Summary

Section 1 - General

Product Description

Overview of MIC 1400 controller features, displays, control, and alarms.

Section 2 - Installation & Wiring

Installation & Wiring

Guidelines for physically installing the controller into a panel and proper mounting.

Preparations for Wiring

Instructions and considerations for wiring to minimize electrical noise effects.

Input Connections

How to connect various input types like thermocouple, RTD, mV, mA, and V.

Output Connections

Wiring details for relay, SSR driver, and mADC outputs for different functions.

Section 3 - Configuration & Operation

Operation

Procedures for powering up, keypad usage, and understanding display indicators.

Configuration

How to access and use Enable, Program, and Tune modes for settings.

Pre-Tune Mode

Procedure to set approximate PID parameters for tuning.

Auto-Tune Mode

Procedure to optimize tuning while the instrument is operating.

Manual Tuning Method

Steps for manually adjusting PID parameters like Cycle Time and Bandwidth.

Section 4 - Control Capability

Control Capability

Overview of programmable control functions like Auto Tune, Alarms, and Switching.

Control Responses

Details on Proportional, Integration, and Derivative responses (PID parameters).

Direct;Reverse Operation of Outputs

How Direct/Reverse operation applies to cooling/heating applications for outputs.

On-Off Control

Implementing On-Off control by setting proportional band to zero with hysteresis.

Time Proportioning Control

Achieving control by cycling output on/off within a prescribed period.

Current Proportioning Control

Using mADC output for control based on process value and setpoint with 4-20mA.

Setpoint Adjustment

How to adjust the controller's setpoint and use ramp features for soft start.

Appendix A: Glossary of Terms

Appendix B: Board Layout

PCB Positions

Diagrams showing the location of internal PCBs and jumper configurations.

Appendix C: Hardware Definition Code

Appendix D: Input Range Codes

Thermocouple Input Ranges

Codes and input ranges for various thermocouple types.

RTD Input Ranges

Codes and input ranges for RTD sensors.

DC Input Ranges

Codes and input ranges for DC voltage and current inputs.

Appendix E: Specifications

Input Specifications

Details on input types, resolution, impedance, and sensor break protection.

Output Specifications

Technical details for Relay, SSR, and DC outputs, including ratings and isolation.

Control Specifications

Parameters for Auto Tune, Proportional Bands, Auto Reset, Rate, and Manual Reset.

Performance and Operating Conditions

Environmental limits, voltage, resistance, accuracy, and physical dimensions.

Appendix F: Order Matrix

Appendix G: Software Reference Sheet

Warranty and Return Statement

Partlow MIC 1400 Specifications

General IconGeneral
DisplayDual 4-digit LED
Control ModeOn/Off, PID
Operating Temperature0 to 50°C (32 to 122°F)
Input TypeThermocouple, RTD, mA, V
Control OutputRelay, SSR, mA, V
Power Supply100-240 VAC
Temperature RangeDepends on sensor type
Accuracy±0.25% of span
MountingPanel Mount
CommunicationOptional RS-485 Modbus RTU
Controller TypeMicroprocessor-based controller