Inline PSU Tester – User’s Guide Page 29
The efficiency measurements confirm that the PSU meets the 80 Plus Gold
efficiency requirements at 20% and 50% loads.
Table 22
Test Results:
- The PSU failed to assert the PWR_OK to high level. Therefore, the PSU Tester
reported T3 as N/A (not available). A few seconds later we noticed smoke and
burning smell from the PSU, and we immediately turned it off from the wall. This
PSU was being used for a few years and was replaced as the PC used to shut down
after a few minutes.
Figure 26
Disclaimer
This product is not warranted nor intended to be used for medical, life support,
lifesaving, critical control or safety applications, unless pursuant to an express written
agreement with PassMark Software. Furthermore, PassMark Software does not
authorize this product for use as critical components in life-support systems where a
malfunction or failure may reasonably be expected to result in significant injury to the
user. The inclusion of this PassMark Software product in life-support systems
application implies that the manufacturer assumes all risk of such use and in doing so
indemnifies PassMark Software against all charges.