Page #1 background image
Heat Pump System that Saves Energy and Provides Outstand-
ing Heating and Cooling All Year
all-season comfort in any climate
high energy savings capability
suitable for new construction or replacement
FEATURES/BENEFITS
System indoor and outdoor sections offer outstanding perfor-
mance in either the Cooling or Heating mode
HEAT PUMP SYSTEM ENERGY SAVINGS OPPORTUNITY
Electrical energy consumption is always a prime concern when
selecting an air-conditioning system for a commercial applica-
tion. An easy, effective way to save energy is to install a heat
pump. Should your building plans call for one, consider a
matched PH1S/PF1B heat pump system. This system not only
provides highly efficient cooling, it also doubles as a clean, safe,
efficient source of heat. In fact, it is capable of delivering ap-
proximately 3 units of heat energy for each unit of electrical
power consumed.
HEAT PUMP UNIQUENESS The outstanding performance
of this heat pump system is due to the heat pump’s ability to ab-
sorb and transfer heat from outdoors to indoors for heating,
and from indoors to outdoors for cooling.
VARIABLE REFRIGERATION CIRCUITING (VRC) PH1S
UNITS For that extra measure of heat pump performance,
variable refrigeration circuiting provides improved heat transfer.
The design combines check valves and fixed-bore refrigerant
metering to improve the circuiting of the outdoor coil. This cir-
cuiting achieves the best performance possible during both the
heating and cooling modes. The VRC feature provides three
valuable benefits that ordinary heat pump systems cannot
match:
Improved heat transfer, resulting in a higher Coefficient of
Performance (COP), especially at temperatures below 47 F.
Improved reliability, by ensuring the proper quality of refriger-
ant is flowing to the compressor.
Faster coil defrosting.
PH1S APPLICATION VERSATILITY Whether for a new ap-
plication or replacement, these split system heat pumps offer
time-proven performance for year-round comfort in any climate.
RUGGED LONG LIFE COMPRESSOR PH1S UNITS
Model PH1S outdoor sections are equipped with semi-hermetic
compressors, which are famous throughout the industry for their
reliability. These compressors have vane-type oil pumps with
positive oil pressure, an oil pressure regulating valve, class F
stator windings, capacity reduction, oil level sight glass, and
service valves. A Cycle-LOC™ device in the PH1S control box
holds the compressor offline if any operational or safety device-
trips the compressor. The unit can be reset manually at the
thermostat.
FEATURES TO CONSIDER, PH1S UNITS
Controls for Performance Efficiency The PH1S090 unit of-
fers simple operating controls and components designed for
performance dependability. The semi-hermetic compressor is
engineered for long life and durability. The compressor includes
overload protection and compressor vibration isolation for fur-
ther enhancement of quiet operation. The high-pressure switch
protects the entire refrigeration system from abnormally high
operating pressures. A loss-of-charge switch is also provided to
protect the system against low charge conditions.
The unit also includes anti-short-cycling protection which pro-
tects the compressor from the damage that can be caused by
rapid compressor cycling. The 24-v control circuit transformer
permits quick, easy wiring of standard and programmable 24-v
thermostats.
Latest safety standards for PH1S090 units are assured through
UL (Underwriters’ Laboratories) and UL, Canada approval.
The PH1S090 utilizes a state-of-the-art defrost board with field
configurable timed defrost cycles. The defrost board may be
easily configured for defrost cycles of 30, 50, or 90 minutes, de-
pending upon the application.
PH1S090
PF1B090
SPLIT SYSTEM
HEAT PUMP WITH
AIR HANDLING UNIT
Model PH1S
With PF1B
7
1
2
Tons
Form No. PDS PH1S.90.1
Question and Answer IconNeed help?

Do you have a question about the Payne PH1S and is the answer not in the manual?

Payne PH1S Specifications

General IconGeneral
RefrigerantR-410A
Voltage208/230
Phase1
Cooling Capacity (BTU/h)36000
Heating Capacity (BTU/h)36000

Summary

Features and Benefits

Heat Pump System Energy Savings Opportunity

Explains energy savings of heat pump systems for commercial applications.

Variable Refrigeration Circuiting (VRC) - PH1S Units

Details how VRC improves heat transfer and performance in heat pumps.

PH1S Application Versatility

Rugged Long Life Compressor PH1S Units

Highlights the reliability and features of the semi-hermetic compressors used in PH1S units.

Heat Pump Performance - Enhanced by Variable Refrigeration Circuiting - PH1S Units

Model Number Nomenclature

ARI Capacities

Physical Data

Outdoor Unit

Lists physical specifications for the PH1S outdoor unit.

Indoor Unit

Details physical specifications for the PF1B indoor unit.

Accessories - Outdoor Unit

Motormaster® III Head Pressure Control

Describes the function of the Motormaster III for head pressure control.

Dimensions - Outdoor Unit

Dimensions - Indoor Unit

Selection Procedure (with example)

Determine Cooling and Heating Load Requirements

Steps to determine the required cooling and heating capacity for the application.

Select System That Satisfies Load Requirements

Guidance on selecting a system that meets the calculated load requirements.

Determine the Heating Capacity of Selected System

Process for verifying heating capacity and determining supplemental heat needs.

Performance Data

Nominal Capacities

Presents the nominal cooling and heating capacities of the unit combinations.

Integrated Heating Capacities

Shows heating capacities under various outdoor temperature conditions.

Combination Ratings - Cooling

Provides detailed cooling performance ratings based on different conditions.

Indoor Unit Accessory Coils

Indoor Unit Fan Performance Data - 0.0-1.2 ESP

Fan performance data at various external static pressures.

Typical Piping and Wiring

Electrical Data

Outdoor Unit Electrical Specifications

Electrical specifications for the PH1S outdoor unit, including power requirements.

Indoor Unit Electrical Specifications

Electrical specifications for the PF1B indoor unit, including fan motor and power supply.

Electric Heater Data - Indoor Unit

Electric Heater Specifications

Provides data on capacity, MCA, and MOCP for electric heater accessories.

Controls

Sequence of Operation - PH1S090 Outdoor Unit with PF1B090 Indoor Unit

Describes the operational sequence for cooling, heating, and defrost modes.

Typical Control Wiring Schematic

Application Data

Operating Limits

Lists the operational limits for the heat pump system components.

Refrigerant Charge and Piping Selection Data

Guide Specifications — PH1S090 Outdoor Unit

Part 1 - General

General information covering system description and quality assurance.

D. Compressor/Motor Assembly

Describes the semi-hermetic compressor and its associated motor assembly.

F. Controls and Safeties

Lists the required operating controls and safety features for the unit.

Guide Specifications — PH1S090 Outdoor Unit (cont)

Guide Specifications — Indoor Unit

Part 1 General

General information for the indoor unit, including system description and quality assurance.

1.01 System Description

Defines the indoor unit as an air-handling unit for commercial heat pump systems.

1.02 Quality Assurance

Outlines the standards and certifications for the indoor unit.

Part 2 - Products

Details the specifications for the indoor unit equipment.

2.01 Equipment

Specifies the components and construction of the indoor unit.

3. Electric Heaters

Specifies the electric heater accessories, including power and wiring.