EasyManua.ls Logo

PCE Instruments PCE-322A User Manual

PCE Instruments PCE-322A
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User's Manual
Data Logger PCE-322A
Please read this user's manual thoroughly before using this unit
and keep it properly for your future reference.
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com

Other manuals for PCE Instruments PCE-322A

Question and Answer IconNeed help?

Do you have a question about the PCE Instruments PCE-322A and is the answer not in the manual?

PCE Instruments PCE-322A Specifications

General IconGeneral
BrandPCE Instruments
ModelPCE-322A
CategoryData Loggers
LanguageEnglish

Summary

Safety

Environment Conditions

Specifies altitude, humidity, and operating temperature limits for safe operation.

Maintenance Guidelines

Guidelines for servicing and cleaning the instrument using soft cloth.

Safety Symbol Identification

Identifies the CE symbol indicating compliance with EMC standards.

General Description

Technical Specifications

Meter Description

LCD Display Description

Operation Instructions

Frequency Weighting Selection

How to select between A and C frequency weighting modes.

Backlight Control

Controls the LCD backlight, turning on/off and auto-off after inactivity.

Data Hold Function

Freezes the current reading on the LCD by pressing the HOLD button.

Level Range Selection

Circularly selects measurement ranges like Lo, Med, Hi, and Auto.

Power On/Off Operation

Instructions for turning the meter on and off using the power key.

MAX/MIN Measurement Mode

Enters MAX/MIN mode to display captured maximum and minimum sound levels.

FAST/SLOW Response Selection

Selects between FAST (125ms) and SLOW (1s) time weighting for measurements.

Date & Time Setting Procedure

Procedure to set the meter's date and time using the SET key and navigation.

Time/Date Display Toggle

Toggles the display between current time (HH:MM:SS) and current date (YYYY-MM-DD).

REC Recording Function

Starts/stops data recording by holding the REC key, with 'Full' indicator for memory limit.

AC/DC Signal Output

Describes the earphone outlet for AC/DC signal output and grounding.

External Power Supply

Details the requirements for external DC 9V power supply input, including polarity and connector size.

Calibration Procedure

Calibration Steps and Settings

Steps to set switch settings, insert microphone into calibrator, and adjust potentiometer.

Recalibration Recommendation

Informs that the meter is pre-calibrated and recommends annual recalibration.

Basic Operation

Battery Installation and Indicator

Instructions for battery installation and recognizing the low battery icon.

AC Adapter Connection

How to connect the AC adapter to the DC 9V connector on the side panel.

Operating Procedures

Power On and Range Selection

Steps to power on the meter and select the desired level range.

Weighting and Response Time

Selecting dBA/dBC weighting and FAST/SLOW response times for measurement.

MAX/MIN Noise Level Measurement

Using the button to measure and display maximum and minimum noise levels.

Meter Placement and Distance

Guidance on holding the meter or using a tripod and optimal distance from the sound source.

Viewing Time and Date

How to view current time or date using the SET key.

Software Installation

Software Interface Introduction

Menu, Toolbar, and File Management

Introduces the software's menu, toolbar icons for file operations, and saving/opening data.

Time and Date Configuration

Details the function for adjusting the meter's time and date based on PC settings.

Real-time Data Monitoring and Graphing

Describes starting/stopping real-time recording and viewing data curves with zoom capabilities.

PC Connectivity and Data Transfer

Instructions for connecting/disconnecting the meter with the PC and uploading recorded data.

Real-time Display Parameters

Explains various parameters shown in the real-time display like Start/End Time, MAX/MIN data, Unit, etc.

A-B Graph Analysis and Datalogger Setup

How to create an A-B graph and access datalogger setup options.

Data Download and Memory Clearing

Functions to upload recorded data and clear the meter's memory.

PC Software Operation

Launching Software and Initial Setup

Steps to launch software, connect meter, and configure initial settings like time/date and sample rate.

Real-time Monitoring and Data Analysis

Starting real-time monitoring, selecting working status, and analyzing data between points on the graph.

Graph Zooming and Navigation

Performing zoom out, zoom in, and zoom A operations on the graph.

Graph Zoom and Full View

Details on using toolbar icons for zooming out and displaying the full graph.

Shutting Down the Meter via PC

Shutting down the meter via the PC software after measurement is complete.

Important Notes

Included Accessories