TECHNICAL CHARACTERISTICS
Power supply
Voltage
230 V~ ± 10% 50/60 Hz
Max power ~ 7 VA
Cold room conditions
Working temperature -5 - 60°C
Storage temperature -10 - 70°C
Relative humidity Less than 90%
General characteristics
Type of sensors that can be connected NTC 10K 1%
Resolution 0.1°C
Sensor read precision ± 0.5°C
Read range -45…+45
ECP200 BASE 4 - Output characteristics - max applicable load (230 V AC)
Compressor 1500 W (AC3)
Elements 3000 W (AC1)
Fans 500 W (AC3)
Room light 800 W (AC1)
Alarm contact (non-powered contact) 100 W (BASE 4 A version only)
ECP200 BASE 2 - Output characteristics - max applicable load (230 V AC)
Compressor (non-powered contact) 1500W (AC3)
Room light (non-powered contact) 800W (AC1)
Alarm contact 100W (BASE 2 A version only)
Dimensional characteristics
Dimensions 19.3 cm x 7.9 cm x 20.3 cm (HxDxL)
Insulation / mechanical characteristics
Box protection rating IP65
Box material Self-extinguishing ABS
Type of insulation Class II
CHAP. 4 - Technical characteristics