10
ENIEE
Excelion 2000
Model Version
Cutting head: ROLL CUT
Power in Watts 2000*
Weight (excluding cutting tool and safety guard) in kg 5.4
Dimensions (l x w x h) in mm 1,800 x 450 x 225
Cutting diameter in mm 340
Rotational speed in rpm 2,000 to 6,200
Battery life Depending on the use and type of battery
■ DESCRIPTION AND TECHNICAL CHARACTERISTICS
Determination of the sound levels and vibration rates is based on the operating conditions at the nominal maximum speed.
* Optimal functioning will be obtained with a tool whose serial number is higher than 53P00821 plus a 700 battery (starting
from serial no. 56N07968) or an 1100 battery (starting from serial no. 56N01725)
Maximum weighted acoustic pressure level A (ref. 20 µPa) at the user's position L
pA
= 84 dB(A) K = 2.5 dB(A)
Weighted peak sound pressure level C (ref. 20 µPa) at the user's position L
pC
< 130 dB(C)
Values dened according to sound measurement standards NF EN ISO 11201 and NF EN ISO 3744.
Symbol Value Unit Reference Comment
L
WAm
92 dB(A) 1 pW Measured sound power level
L
WAg
93 dB(A) 1 pW Guaranteed sound power level
The recording of the measured sound power level and of the guaranteed sound power level has been performed according
to a procedure in accordance with directive 2000/14/EC appendix V.
Values measured at maximum rated speed*
a
h
value
of the
right wrist
measured
in m/s²
a
h
value
of the
left wrist
measured
in m/s²
MultiCut
Ø3 wire 1.7 2.1
Ø3 wire 1.7 2
Twin blade 1.5 1.3
8 teeth 2.4 2
RollCut
Ø3 wire 1 1.3
Ø3 wire 1.9 2
TapCut
Ø3 wire 3.8 3.2
Ø3 wire 3.5 3.5
TapCut 2
Ø3 wire 3.9 3.3
Ø3 wire 3.7 1.9
BladeCut
Twin blade 3.5 4.5
Trident 3.5 4.5
Mulching 2.7 2.1
Saw 2.6 2.4
CityCut Blades 1.2 1
Values measured at maximum rated speed in eco
mode*
a
h
value
of the
right wrist
measured
in m/s²
a
h
value
of the
left wrist
measured
in m/s²
MultiCut
Ø3 wire 1.4 1.3
Ø3 wire 1.5 1.2
Twin blade 1 0.9
8 teeth 1.9 1.5
RollCut
Ø3 wire 1 0.8
Ø3 wire 1.6 1.8
TapCut
Ø3 wire 4.4 3.5
Ø3 wire 3.6 2.7
TapCut 2
Ø3 wire 2.6 1.6
Ø3 wire 2.6 1.6
CityCut Blades 1.1 0.8
Vibration emission values according to EN 60745-1, EN ISO 22867:
*Measurement uncertainty: K = 1.5 m/s²
*Measurement uncertainty: K = 1.5 m/s²