PelPro Cast Pellet Stove • 7093-600 • 07/13/16 pelprostoves.com2 4
Troubleshooting
Troubleshooting
Blockage Related
Fire starts but goes out
• Conrm rebox is clean and clear (Zone 1)
- Ensure repot holes are clear
• Inspect stove body (Zone 2)
- Conrm exhaust probe is connected
- I n spect an d clean th e exh au st ou tlet
• Conrm exhaust path is clean and clear (Zone 3)
Starts and stops frequently in automatic mode
• D etermi n e i f y ou r room i s ex peri en ci n g vary i n g temperatu res d u e to repeated open i n g /
closi n g of d oors or w i n d ow s— correct i f n ecessary
• Examine stove body (Zone 2)
- Inspect ambient probe and conrm that at least 2” is exposed outside of stove
b od y
Slow or smoky start-up and/or lazy ame
• Conrm exhaust path is clean and clear; clean your repot and behind your bafes
inside your rebox (Zone 3)
• Examine stove body (Zone 2)
- A li g n i g n i ter so i t i s properly placed an d cen tered
- Review fuel quality (see Pellet Fuel
information on page 5)
1
Z o n e
1
Z o n e
2
Z o n e
2
Z o n e
3
Z o n e
3
Z o n e