10. Technical data
5P2R / S5P2R
> 24 <
Capacity cubic meters per hour 
Total Head in meters 
5P2R - S5P2R
/ 50 Hz
5P2R
Max. ambient temperature: . . . . .50°C
Max. water temperature: . . . . . . .52°C
pH-range: . . . . . . . . . . . . . . . . . . . . . .4-9
Protection type: . . . . . . . . . . . . . . .IPX5
Insulation class: . . . . . . . . . . . . . . . . . .F
Revolutions (rpm): . . . . . .approx. 2850
Max. noise level: . . . . . . . . . .75 dB(A)
S5P2R
Max. salt content in water: . . . . .0,4%
Max. ambient temperature: . . . . .50°C
Max. water temperature: . . . . . . .42°C
pH-range: . . . . . . . . . . . . . . . . . . . . . .4-9
Protection type: . . . . . . . . . . . . . . .IPX5
Insulation class: . . . . . . . . . . . . . . . . . .F
Revolutions (rpm): . . . . . .approx. 2850
Max. noise level: . . . . . . . . . .75 dB(A)
Wiring diagram
380-420 V / 50 Hz
3 x 400V
Ha – Main phase
Hi – Auxiliary phase
TW – Thermostatic protection
switch
C – Condenser
Wiring diagram
220-240 V / 50 Hz
5P2R S5P2R P1 P2 Motor
5P2RB-1 S5P2RB-1 420 W 250 W 220-240 V
5P2RC-1 S5P2RC-1 630 W 370 W 220-240 V
5P2RD-1 S5P2RD-1 1000 W 550 W 220-240 V
5P2RE-1 S5P2RE-1 1190 W 750 W 220-240 V
5P2RF-1 S5P2RF-1 1590 W 1100 W 220-240 V
5P2R S5P2R P1 P2 Motor
5P2RB-3 S5P2RB-3 420 W 250 W 380-420 V
5P2RC-3 S5P2RC-3 600 W 370 W 380-420 V
5P2RD-3 S5P2RD-3 880 W 550 W 380-420 V
5P2RE-3 S5P2RE-3 1130 W 750 W 380-420 V
5P2RF-3 S5P2RF-3 1590 W 1100 W 380-420 V
See also Page 18,