6.3.3.5 Regeneration time
Set the time when regeneration will take place.
1. Press .
ð Regeneration time flashes.
2. Adjust displayed time with and .
ð Default setting: 2:00am.
3. Press to validate the selection and advance to the next
parameter using or .
6.3.3.6 Days override (762 controller only)
Set the number of days for calendar override.
1. Press .
ð Number of days flashes.
2. Adjust displayed number with and .
ð Default time for days override: 0 day (disabled).
ð Days can be adjusted from ½ (0.5) to 99 days.
3. Press to validate the selection and advance to the next
parameter using or .
6.3.3.7 Days between regeneration (742 controller only)
Set the number of days between regeneration.
1. Press .
ð Number of days flashes.
2. Adjust displayed number with and .
ð Set to 0 to program as a 7-day timer.
ð Days can be adjusted from ½ (.5) to 99 days.
3. Press to validate the selection and advance to the next
parameter using or .
6.3.3.8 Amount of brine used per regeneration
Set desired brine amount in g/L.
1. Press .
ð Setting flashes.
2. Adjust displayed settings with and .
3. Press to validate the selection and advance to the next
parameter using or .