Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Programming
Ref. MKT-IM-012 / D - 03.02.2022 53 / 110
6.3.3.9 Estimated capacity
Info
Note
The system capacity is displayed in kilograms equivalent CaCO
3
of hardness removed
before a regeneration is necessary.
The system capacity is calculated by the Logix software, using the resin volume, brine
dosage and hardness settings.
This parameter can be override for 762 controller and is view only for 742 controller.
Set the estimated capacity on the controller.
1. Press .
ð The amount number flashes.
2. Adjust displayed capacity with and .
3. Press to validate the selection and advance to the next
parameter using or .
6.3.3.10 Hardness (762 controller only)
Set inlet water hardness at installation site.
1. Press .
ð The hardness number flashes.
2. Adjust displayed hardness number with and .
3. Press to validate the selection.
ð Initial programming is now complete. The controller will
return you to the normal operation mode.