EasyManua.ls Logo

Pentair CODELINE 40E100 - Page 7

Pentair CODELINE 40E100
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 7 of 12
REPLACING ELEMENTS (CONTD…)
7. Lubricate element seals sparingly with the element manufacturers recommended
lubricant or with glycerin.
8. Insert each element with the brine seal (typically a U-cup seat) installed on the upstream
end with its lip facing upstream.
9. Install the interconnectors between multiple elements as each succeeding element is
installed.
10. Push each element downstream into the shell as it is installed until the element is fully
engaged with the downstream head. If the elements are hard to push, make sure the
brine seal is properly installed and you are pushing from the upstream end. When all the
elements are fully inserted into the vessel, install the upstream head with the adapter
fitted if required, as described in paragraphs 4 to 6 on page 6.
11. Reconnect piping to vessel as described in Remaking Pipe Connection to End Plug
on page 11.
12. Pressurize the vessel. Inspect for leaks at connections to the vessel and all around
the vessel itself. If any leaks occur, release pressure from the vessel and tighten the
fittings as necessary. Then pressurize vessel and check for leaks again.
CAUTION
System malfunctions and element damage may result if
elements are installed in the wrong direction.
.
NOTE
On some systems it may
be easier
to install
the
piping
connections
before
the
head
is installed.
If so, please proceed with Steps 10 & 11.
.
CAUTION
DO NOT tolerate any leaks. Leaks can
result in corrosion
and eventual
catastrophic vessel failure.
.

Related product manuals