HEAD DISASSEMBLY
Head Component Identification Head Disassembled
HEAD ASSEMBLY
1. Use only head components in as-new
condition. Use new O-rings each time the
head is assembled.
2.
Cover O-rings with a this even layer of
Parker Super
O-Lube
silicone lubricant
or the lubricant recomm
ended by your
element supplier.
Lubricating Plug seals and O-rings
3. Assembly the Adapter Seal into the
groove in the End Plug.
Inserting Permeate Port Seal
4. Hold Bearing Plate with the 3 ½”
diameter stepped surface facing towards
you. From this side, insert the smaller
machined end of the stainless-steel
Feed/ Concentrate Port through the
larger outer hole.
NOTE
Glycerin is a commercially available lubricant that
will not foul elements. However, silicone lubricant is
recommended for this application.
.