PRO-Reverse Osmosis Water Filtration System Installation and Operating Instructions 5
Figure 2
INSTALLATION
Drinking Water Faucet
Red
Blue
White
Manifold
Optional Tank Installation
Tank
Valve
Supply
Adapter
Cold
Water
Drain
Clamp
Membrane
Housing
Prefilter
Housing
Green
Post-polishing
Filter Housing
Prefilter
Manifold
Cover
Storage
Tank
Post-polishing
Filter
Membrane
Figure 1
Installing the Water Supply Adapter
NOTE: Read all installation and operating instructions
before installing and using your RO system.
The supply adapter fits 1/2-NPS supply threads. If local codes
permit, it may be used to connect the PRO to the cold water
supply line. If local codes do not permit the use of the supply
adapter, alternate connectors can be obtained from your local
plumbing wholesaler.
See Figure 2.
1. Turn off cold water supply line. If cold water line does not
have a shut-off valve under the sink, you should install one.
2. Turn on the cold water faucet and allow all water to drain
from line.
3. Disconnect cold water line from the threaded stub on
bottom of main faucet.
4. Apply plumber tape onto threads of faucet stub and supply
adapter. Screw the water supply adapter to the threaded
faucet stub as shown.
5. Using the nut that previously connected the cold water line
to the faucet, screw the cold water line to the male supply
adapter threads.