11. Day Override (Display Code DO)
Press the Extra Cycle button. Use this display to set the
Day Override. This setting specifies the maximum number
of days between regeneration cycles. If the system is set to
a timer-type control, the day override setting determines
how often the system will regenerate. A metered system
will regenerate regardless of usage if the days since last
regeneration cycle equal the day override setting. Setting
the day override value to “OFF” disables this function. This
option setting is identified by “DO” in the upper left hand
corner of the screen. Use the Up and Down buttons to adjust
the value as needed.
Range: Off-99 days
12. Regeneration Time
Press the Extra Cycle button. Use this display to set the
Regeneration Time. This setting specifies the time of day
the control will initiate a delayed, manually queued, or
day override triggered regeneration. This option setting is
identified by “RT” in the upper left hand corner of the screen.
Use the Up and Down buttons to adjust the value as needed.
13. Regeneration Cycle Step Times
Press the Extra Cycle button. Use this display to set
the Regeneration Cycle Step Times. The different
regeneration cycles are listed in sequence based on the
valve type selected for the system, and are identified by an
abbreviation in the upper left-hand corner of the screen. The
abbreviations used are listed below. If the system has been
configured with the “OTHER” valve type, the regeneration
cycles will be identified as R1, R2, R3, R4, R5, and R6. Each
cycle step time can be set from 0 to 199 minutes. Setting a
cycle step time to 0 will cause the control to skip that step
during regeneration, but keeps the following steps available.
Use the Up and Down buttons to adjust the value as needed.
Press the Extra Cycle button to accept the current setting
and move to the next parameter.
Abbreviation Cycle Step
BD Brine Draw
BF Brine Fill
BW Backwash
RR Rapid Rinse
SV Service
Range: 0-199 minutes
MASTER PROGRAMMING MODE
CONTINUED
14. Day of Week Settings
Press the Extra Cycle button. Use this display to set the
regeneration schedule for a system configured as a Day of
Week control. The different days of the week are identified as
D1, D2, D3, D4, D5, D6, and D7 in the upper left-hand corner of
the display. Set the value to “ON” to schedule a regeneration or
“OFF” to skip regeneration for each day. Use the Up and Down
buttons to adjust the setting as needed. Press the Extra Cycle
button to accept the setting and move to the next day. Note that
the control requires at least one day to be set to “ON.” If all 7
days are set to “OFF”, the unit will return to Day One until one
or more days are set to “ON.
15. Current Day (Display Code CD)
Press the Extra Cycle button. Use this display to set the current
day on systems that have been configured as Day of Week
controls. This setting is identified by “CD” in the upper left-
hand corner of the screen. Use the Up and Down buttons to
select from Day 1 through Day 7.
16. Flow Meter Type (Display Code FM)
Press the Extra Cycle button. Use this display to set the type
of flow meter connected to the control. This option setting is
identified by “FM” in the upper left-hand corner of the screen.
Use the Up and Down buttons to select one of the seven available
settings.
t0.7 Fleck 3/4-inch Turbine Meter
P0.7 Fleck 3/4-inch Paddle Wheel Meter
t1.0 Fleck 1-inch Turbine Meter
P1.0 Fleck 1-inch Paddle Wheel Meter
t1.5 Fleck 1-1/2 inch Turbine Meter
P1.5 Fleck 1-1/2 inch Paddle Wheel Meter
P2.0 Fleck 2-inch Paddle Wheel Meter
GEn Generic/Other Meter
17. Meter Pulse Setting (Display Code K)
Press the Extra Cycle button. Use this display to specify the
meter pulse setting for a non-standard flow meter. This option
setting is identified by “K” in the upper left-hand corner of
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
18. End of Master Programming Mode
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.