USER PROGRAMMING MODE
User Programming Mode Options
Abbreviation Parameter Description
DO Day Override The timer’s day override
setting
RT Regeneration
Time
The time of day that the
system will regenerate
(meter delayed, timeclock,
and day-of-week systems)
H Feed Water
Hardness
The hardness of the inlet
water - used to calculate
system capacity for metered
systems
RC or SF Reserve Capacity The fixed reserve capacity
CD Current Day The current day of week
NOTE: Some items may not be shown depending on timer
configuration. The timer will discard any changes
and exit User Mode if any button is not pressed for
sixty seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identified by “DO” in the upper left hand corner
of the screen.
3. Press the Extra Cycle button. Use this display to adjust
the Regeneration Time. This option setting is identified by
“RT” in the upper left hand corner of the screen.
4. Press the Extra Cycle button. Use this display to adjust
the Feed Water Hardness. This option setting is identified
by “H” in the upper left hand corner of the screen.
Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the
Fixed Reserve Capacity. This option setting is identified by
“RC” or "SF" in the upper left-hand Corner
of the screen.
6. Press the Extra Cycle button. Use this display to set the
Current Day of the Week. This option setting is identified by
“CD” in the upper left hand corner of the screen.
7. Press the Extra Cycle button to end User
Programming Mode.
FLECK SXT Timer Service Manual • 9