INTELLIPH
®
ACID DISPENSER Installation and User’s Guide INTELLIPH
®
ACID DISPENSER Installation and User’s Guide
1
IntellipH
®
Acid Dispenser System Overview
This manual describes how to install and setup the IntellipH
®
Acid Dispenser System which
consists of the IntellipH controller and dispenser container.
Operating IntellipH
®
Controller
The IntellipH controller adds acid to the pool every hour. The dispense amount is based
on the user’s settings. The amount of acid added each hour can be quickly changed by
pressing either the MORE or LESS button with a range of 1% - 100% in 1% increments. If
0% is selected, no acid will be dispensed.
All acid for the IntellipH acid dispenser system is stored in a four gallon storage canister
with a built-in pump. The acid is pumped from the canister via a tube that is provided in
the kit. The tube is attached to a saddle clamp which is mounted after the heater directly
into the water return line.
After each dose, the IntellipH controller control panel display will show a 60-minute
countdown timer. When the timer equals zero, the pump on the canister is activated and
acid is pumped into the pool’s main waterline. The 60 minute timer will restart again.
Note: After an IntelliChlor
®
Salt Chlorine Generator (SCG) is connected to the IntellipH
controller, the cell sanitizer output will be adjusted through the IntellipH controller menu
and NOT through the IntellliChlor SCG cell. Set the IntelliChlor SCG output from the
SET CELL OUTPUT menu on the IntellipH controller. The More and Less buttons on
IntelliChlor cell will be disabled.
IntellipH Acid Dispenser System Kit Contents
• One IntellipH Controller Control Panel
• 3-1/2 gallon storage canister, with pump
• 15 ft Acid resistant tubing from canister to cell
• Two saddle clamps (1.5” and 2”)
• One Injection fitting
Annual Tube Replacement
IMPORTANT NOTICE: It is reccommened to replace the pump head tube once a season
(yearly), see page 10 for pump head tube replacement instructions.
Annual Feed Line Inspection
Annually inspect the 1/4” feed line. Replace if required.