PLUMBING CONNECTIONS
7KH 0DVWHU7HPS
®
KHDWHU KDVWKH XQLTXH FDSDELOLW\ RI
GLUHFW VFKHGXOH 39& SOXPELQJ FRQQHFWLRQV $ VHW RI
EXONKHDG ¿WWLQJV LV LQFOXGHG ZLWK WKH 0DVWHU7HPS
KHDWHU WR LQVXUH FRQIRUPLW\ ZLWK 3HQWDLU¶V UHFRPPHQGHG
39&SOXPELQJSURFHGXUH2WKHUSOXPELQJFRQQHFWLRQVFDQ
EHXVHG6HH
)LJXUHIRUSOXPELQJFRQQHFWLRQV
CAUTION
Before operating the heater on a new installation, turn on
the circulation pump and bleed all the air from the filter
using the air relief valve on top of the filter. Water should
flow freely through the heater. Do not operate the heater
unless water in the pool/spa is at the proper level. If a
manual by-pass is installed, temporarily close it to insure
that all air is purged from the heater.
WATER CONNECTIONS
7KH KHDWHU UHTXLUHV SURSHU ZDWHU ÀRZ DQG SUHVVXUH IRU LWV
RSHUDWLRQ6HH)LJXUHIRUWKHUHFRPPHQGHGLQVWDOODWLRQ7KH
¿OWHUSXPSGLVFKDUJHVWRWKH¿OWHUWKH¿OWHUGLVFKDUJHVWRWKH
KHDWHUDQGWKHKHDWHUGLVFKDUJHVGLUHFWO\WRWKHSRRORUVSD
$PDQXDOE\SDVVYDOYHVKRXOGEHLQVWDOOHGDFURVVWKHKHDWHU
ZKHQ WKH SXPS ÀRZ H[FHHGV *30 /30 6HH
³:$7(5)/2:5$7(´7DEOHRQ
SDJHIRUVHWWLQJRI
WKHPDQXDOE\SDVVYDOYH
0DNHVXUHWKDWWKHRXWOHWSOXPELQJIURPWKHKHDWHUFRQWDLQV
QRVKXWRIIYDOYHVRURWKHUÀRZUHVWULFWLRQVWKDWFRXOGSUHYHQW
ÀRZWKURXJKWKHKHDWHUH[FHSWIRUSRROLQVWDOODWLRQVDVQRWHG
EHORZRUZLQWHUL]LQJYDOYHVZKHUHQHHGHG7RVZLWFKÀRZ
EHWZHHQWKHSRRODQGVSDXVHDGLYHUWHUYDOYH'RQRWXVH
DQ\YDOYHWKDWFDQVKXWRIIWKHÀRZ
,QVWDOOWKHFKHPLFDOIHHGHUGRZQVWUHDPRIWKHKHDWHU,QVWDOODFKHPLFDOUHVLVWDQWRQHZD\FKHFNYDOYHEHWZHHQWKH
KHDWHUDQGWKHFKHPLFDOIHHGHUWRSUHYHQWEDFNVLSKRQLQJWKURXJKWKHKHDWHUZKHQWKHSXPSLVRII
NOTICE:,IWKHKHDWHULVSOXPEHGLQEDFNZDUGVLWZLOOF\FOHFRQWLQXRXVO\0DNHVXUHSLSLQJIURP¿OWHULVQRWUHYHUVHG
ZKHQLQVWDOOLQJKHDWHU
&RQQHFWWKHKHDWHUGLUHFWO\WR´39&SLSHXVLQJWKHLQWHJUDOXQLRQVSURYLGHG+HDWVLQNVDUHQRWUHTXLUHG7KHORZ
WKHUPDOPDVVRIWKHKHDWHUZLOOSUHYHQWRYHUKHDWLQJRIWKHSLSLQJFRQQHFWHGWRWKHSXPSHYHQLIWKHKHDWHUVKXWVGRZQ
XQH[SHFWHGO\,I\RXDUHXVLQJDÀH[LEOHFRUUXJDWHGKRVHIRUDERYHJURXQGV\VWHPVXVHRQO\3HQWDLUDSSURYHGÀH[LEOH
KRVHNLWV31IWDQG31IW
2FFDVLRQDOO\DWZRVSHHGSXPSZLOOQRWGHYHORSHQRXJKSUHVVXUHRQWKHORZVSHHGWRRSHUDWHWKHKHDWHU,QWKLVFDVHUXQ
WKHSXPSDWKLJKVSHHGRQO\WRRSHUDWHWKHKHDWHU,IWKLVGRHVQRWVROYHWKHSUREOHPGRQRWWU\WRUXQWKHKHDWHU,QVWHDG
FRUUHFWWKHLQVWDOODWLRQ
'RQRWRSHUDWHWKHKHDWHUZKLOHDQDXWRPDWLFSRROFOHDQHULVDOVRRSHUDWLQJ,IWKHFLUFXODWLRQSXPSVXFWLRQLVSOXJJHG
IRUH[DPSOHE\OHDYHVWKHUHPD\QRWEHDGHTXDWHÀRZWRWKHKHDWHU'RQRWUHO\RQWKHSUHVVXUHVZLWFKLQWKLVFDVH
Pool
Main
Drain
Spa
From Pool
3-Way
Valve
3-Way
Valve
3-Way
Valve
Chlorinator
Heater
Pump
Check Valve
Filter
Figure 4.
Section 3. Installation Instructions
PUMP
FILTER
HEATER
MANUAL
BY-PASS
TO
POOL
GATE
VALVE
FROM
POOL
FROM
FILTER
Figure 3.