125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
6
CONSUMER INFORMATION AND SAFETY
WARNING
The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous.
See below for water temperature guidelines before setting temperature.
 6SDRUKRWWXEZDWHUWHPSHUDWXUHVVKRXOGQHYHUH[FHHG)&$WHPSHUDWXUHRI)&LVFRQVLGHUHG
VDIHIRUDKHDOWK\DGXOW6SHFLDOFDXWLRQLVVXJJHVWHGIRU\RXQJFKLOGUHQ
 'ULQNLQJRIDOFRKROLFEHYHUDJHV EHIRUH RU GXULQJ VSD RU KRW WXEXVH FDQ FDXVH GURZVLQHVV ZKLFK FRXOG OHDG WR
XQFRQVFLRXVQHVVDQGVXEVHTXHQWO\UHVXOWLQGURZQLQJ
 3UHJQDQWZRPHQEHZDUH6RDNLQJLQZDWHUDERYH)&FDQFDXVHIHWDOGDPDJHGXULQJWKH¿UVWWKUHH
PRQWKVRISUHJQDQF\UHVXOWLQJLQWKHELUWKRIDEUDLQGDPDJHGRUGHIRUPHGFKLOG3UHJQDQWZRPHQVKRXOGVWLFN
WRWKH)&PD[LPXPUXOH
 %HIRUHHQWHULQJWKHVSDRUKRWWXEWKHXVHUVKRXOGFKHFNWKHZDWHUWHPSHUDWXUHZLWKDQDFFXUDWHWKHUPRPHWHU6SD
RUKRWWXEWKHUPRVWDWVPD\HUULQUHJXODWLQJZDWHUWHPSHUDWXUHVE\DVPXFKDV)&
 3HUVRQVZLWKDPHGLFDOKLVWRU\RIKHDUWGLVHDVHFLUFXODWRU\SUREOHPVGLDEHWHVRUEORRGSUHVVXUHSUREOHPVVKRXOG
REWDLQWKHLUSK\VLFLDQ¶VDGYLFHEHIRUHXVLQJVSDVRUKRWWXEV
 3HUVRQVWDNLQJPHGLFDWLRQZKLFKLQGXFHGURZVLQHVVVXFKDVWUDQTXLOL]HUVDQWLKLVWDPLQHVRUDQWLFRDJXODQWVVKRXOG
QRWXVHVSDVRUKRWWXEV
WARNING
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater.
Do not use this heater if any part has been under water. Immediately call a qualified service technician to
inspect the heater and to replace any part of control system and gas control which has been under water.
CODE REQUIREMENTS
,QVWDOODWLRQPXVWEHLQDFFRUGDQFHZLWKDOOORFDOFRGHVDQGRUWKHODWHVWHGLWLRQRIWKH1DWLRQDO)XHO*DV&RGH
$16,=DQGWKHODWHVWHGLWLRQRIWKH1DWLRQDO(OHFWULFDO&RGH1)3$86
,QVWDOODWLRQLQ&DQDGDPXVWEHLQDFFRUGDQFHZLWKWKHODWHVW&$1&*$%RUDQG&6$&&DQDGLDQ
(OHFWULF&RGHSDUW
7KHKHDWHUZKHQLQVWDOOHGPXVWEHHOHFWULFDOO\JURXQGHGDQGERQGHGLQDFFRUGDQFHZLWKORFDOFRGHVRULQDEVHQFH
RIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGH$16,1)3$86RULQ&DQDGDLQDFFRUGDQFHZLWKWKH&DQDGLDQ
(OHFWULF&RGHSDUWDVDSSOLFDEOH
Section 2. Warning and Safety Instructions
DANGER
CARBON MONOXIDE GAS IS DEADLY – Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous,
poisonous gas you cannot see or smell.

Table of Contents

Other manuals for Pentair MASTERTEMP 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP 125 and is the answer not in the manual?

Pentair MASTERTEMP 125 Specifications

General IconGeneral
BTU Output125, 000 BTU/hr
Fuel TypeNatural Gas or Propane
Ignition SystemElectronic
Minimum Flow Rate20 GPM
Maximum Working Pressure50 PSI
Efficiency82%
Water Connections1.5 inch
CertificationsANSI Z21.56
Voltage120V