GENERAL SPECIFICATIONS
NOTICE:
s #OMBUSTIONAIRCONTAMINATEDBYCORROSIVECHEMICALFUMESCANDAMAGETHEHEATERANDWILLVOIDTHEWARRANTY
s 4HE#OMBINATION'AS#ONTROL6ALVEONTHISHEATERDIFFERSFROMMOSTAPPLIANCEGASCONTROLS)FITMUSTBEREPLACED
for safety reasons replace it only with an identical gas control.
s 4HEACCESSDOORPANELSMUSTBEINPLACETOPROVIDEPROPERVENTILATION$ONOTOPERATETHEHEATERFORMORETHANlVE
minutes with the access door panels removed.
s 4HISHEATERISDESIGNCERTIlEDBY#3!)NTERNATIONALASCOMPLYINGWITHTHE3TANDARDFOR'AS&IRED0OOL(EATERS
ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas.
s 4HEHEATERISDESIGNEDFORTHEHEATINGOFCHLORINEBROMINEORSALTSYSTEMSWIMMINGPOOLSANDSPAS)TSHOULDNOT be
used as a space heating boiler, or general purpose water heater.
s 4HEHEATERISDESIGNCERTIlEDBY#3!)NTERNATIONALFORINSTALLATIONONCOMBUSTIBLEmOORING3PECIlEDMINIMUM
clearances must be maintained to combustible surfaces (see “Heater Clearances”,
page 18).
s 4HEHEATERSHOULDBELOCATEDINANAREAWHERELEAKAGEOFTHEHEATERORCONNECTIONSWILLNOTRESULTINDAMAGETOTHE
area adjacent to the heater or to the structure. When such locations cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed under the heater. The pan must not restrict air flow.
CONSUMER INFORMATION AND SAFETY
WARNING
The U.S. Consumer Product Safety Commission warns that carbon monoxide is an “invisible killer”. Carbon monoxide
is a colorless and odorless gas.
 &DUERQPRQR[LGHLVSURGXFHGE\EXUQLQJIXHOLQFOXGLQJQDWXUDOJDVDQGSURSDQH
 3URSHULQVWDOODWLRQRSHUDWLRQDQGPDLQWHQDQFHRIIXHOEXUQLQJDSSOLDQFHVLQWKHKRPHLVWKHPRVWLPSRUWDQW
IDFWRULQUHGXFLQJFDUERQPRQR[LGHSRLVRQLQJ
 %HVXUHWKDWIXHOEXUQLQJDSSOLDQFHVVXFKDVKHDWHUVDUHLQVWDOOHGE\SURIHVVLRQDOVDFFRUGLQJWRPDQXIDFWXUHUV
LQVWUXFWLRQVDQGFRGHV
 $OZD\VIROORZWKHPDQXIDFWXUHUVGLUHFWLRQVIRUVDIHRSHUDWLRQ
 +DYHWKHKHDWLQJV\VWHPLQFOXGLQJYHQWVLQVSHFWHGDQGVHUYLFHGDQQXDOO\E\DWUDLQHGVHUYLFHWHFKQLFLDQ
 ([DPLQHYHQWVUHJXODUO\IRULPSURSHUFRQQHFWLRQVYLVLEOHFUDFNVUXVWRUVWDLQV
 ,QVWDOOEDWWHU\RSHUDWHGFDUERQPRQR[LGHDODUPV7KHDODUPVVKRXOGEHFHUWL¿HGWRWKHUHTXLUHPHQWVRIWKH
PRVWUHFHQW8/,$6&6$DQG,$302VWDQGDUGIRUFDUERQPRQR[LGHDODUPV7HVWFDUERQPRQR[LGHDODUPV
UHJXODUO\DQGUHSODFHGHDGEDWWHULHV
Section 2. Warning and Safety Instructions

Table of Contents

Other manuals for Pentair MASTERTEMP 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP 125 and is the answer not in the manual?

Pentair MASTERTEMP 125 Specifications

General IconGeneral
BTU Output125, 000 BTU/hr
Fuel TypeNatural Gas or Propane
Ignition SystemElectronic
Minimum Flow Rate20 GPM
Maximum Working Pressure50 PSI
Efficiency82%
Water Connections1.5 inch
CertificationsANSI Z21.56
Voltage120V